Further information for Dold 0028926 BA9043/003 under-voltage relay 3AC50-400Hz 440V
Technical data
1- / 3-phase
3
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
3/N AC 690 / 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9043
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
3AC 440 V
Time delay
0,5 - 10 s
Approvals and Markings
UKCA
Variant
For 3p3w systems. With adjustable time delay
The undervoltage relay BA9043/003 from Dold is a 3-phase monitoring device for three-phase AC networks without a neutral conductor. It is designed for continuous monitoring of the network voltage and de-energizes output contacts in case of undervoltage to prevent damage to connected devices. The device is part of the VARIMETER series and is particularly suitable for industrial and railway applications where reliable voltage monitoring is required.
Applications
This relay is used in industrial plants, power supply technology, and railway systems, where stable network voltage is critical for the operation of machines and drives. It monitors 3-phase AC networks in the frequency range of 50 to 400 Hz and is designed for rated voltages up to 3 AC 690 V. The BA9043/003 variant is specifically designed for networks without a neutral conductor, with voltage measurement performed between phases L1, L2 and L3.
Functions and Equipment in Detail
The device operates on the rest current principle, meaning the output relay remains inactive in the event of a fault and stays in its resting position. Voltage measurement is performed using arithmetic mean calculation, where individual phases are measured against the third phase. The pickup and dropout values are adjusted via rotary potentiometers on the front of the device, enabling user-friendly and precise adaptation to specific applications. Pickup values are continuously adjustable between 0.85 and 1.05 of the rated voltage, with hysteresis ranging from 0.75 to 0.95 of the pickup value.
Technology Explained Simply
The time delay is adjustable and ranges from 0.5 to 10 seconds. However, this delay is only effective if the network voltage is at least 60 % of the rated voltage. Below 40 % of the rated voltage, the output relay de-energizes immediately to ensure rapid response during severe voltage dips. The devices are insensitive to harmonics, meaning they operate reliably even with network voltages containing harmonic distortions.
Compatibility and Accessories
The relay is suitable for networks with frequencies from 50 to 400 Hz and complies with the standard IEC/EN 60255-1. It features two changeover contacts as output contacts, designed for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A / AC 230 V for make contacts and 1 A / AC 230 V for break contacts according to AC 15. Maximum short-circuit withstand requires a fuse of 4 A gG / gL. The devices are designed for continuous operation and can be operated at temperatures from -20 °C to +60 °C.
Mounting and Installation
The device is mounted on a DIN rail and has a width of 45 mm. The connection terminals are designed for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Mounting is achieved using plus-minus screws with a self-lifting clamp lever. Terminal markings are L1, L2, L3 for network connections and 11, 12, 14 as well as 21, 22, 24 for the two changeover contacts.
Operational Advantages
Integrated LED indicators signal operational readiness (red LED) and activation of the output relay (green LED). This enables quick fault localization and preventive maintenance. Harmonic insensitivity and adjustable pickup and dropout values enhance reliability and adaptability to different network conditions. The devices are designed for use in enclosures and comply with the requirements of overvoltage category III.