Further information for Dold 0028767 BA9043/002 3/N AC50-400Hz 127/220V under-voltage relay 0,5-10s
Technical data
1- / 3-phase
3
Auxiliary voltage
Without
Enclosure design
Switch cabinet
Nominal voltage max.
3/N AC 690 / 400 V
Output contacts
2 C/O contacts
Width
45 mm
Type
BA 9043
Operate delay
Variant
Contact equipping
2 changeover contacts
Nominal voltage
3/N 127/220 V
Time delay
0,5 - 10 s
Approvals and Markings
UKCA, CCC
Variant
For 3p4w systems. With adjustable time delay
The under-voltage relay BA9043/002 from Dold is a 3-phase monitoring device for AC networks with neutral conductor. It is designed for continuous monitoring of network voltage and disconnects connected loads in case of under-voltage or voltage failure, preventing damage to electrical devices. The device is rated for nominal voltages of 3/N AC 127/220 V and can be used in networks with frequencies from 50 to 400 Hz. Measurement is performed via arithmetic mean value calculation, where each phase is measured against the neutral conductor. Device settings are adjusted via rotary potentiometers on the front panel, allowing continuous adjustment of pickup and drop-out values. The pickup value ranges from 0.85 to 1.05 times nominal voltage, while the drop-out value is 0.75 to 0.95 of the pickup value. Time delay is adjustable and ranges from 0.5 to 10 seconds. At voltages below 0.4 times nominal voltage, the output relay drops out immediately; at voltages between 0.4 and 0.6 times nominal voltage, the time delay is active.
Applications
This relay is suitable for industrial applications and railway applications. It monitors 3-phase AC networks and is designed for operation in enclosures. The width is 45 mm, enabling mounting on DIN rail. Operating temperature ranges from -20 to +60 °C, storage temperature from -25 to +60 °C. Maximum operating altitude is 2000 m above sea level. The device is designed for continuous operation and complies with IEC/EN 60255-1.
Functions and Equipment in Detail
The BA9043/002 features two changeover contacts as output contacts, rated for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A/AC 230 V for closing contacts and 1 A/AC 230 V for opening contacts according to IEC/EN 60947-5-1. Electrical life expectancy is at least 200,000 switching cycles at 3 A and AC 230 V, while mechanical life expectancy exceeds 30 million switching cycles. Contacts are equipped with LED indicators for operational readiness (red LED) and contact position (green LED). The device operates on the residual current principle, ensuring the output relay is not activated in case of fault. Harmonic immunity ensures reliable operation even with distorted voltage waveforms.
Technology Explained Simply
Arithmetic mean value measurement enables precise voltage monitoring by measuring each phase against the neutral conductor and averaging the values. The adjustable time delay prevents unwanted disconnections during short-term voltage dips. Settings are adjusted via two rotary potentiometers on the front panel, allowing easy and user-friendly adjustment of pickup and drop-out values as well as time delay. Maximum overload capacity is 1.2 times nominal voltage continuously.
Compatibility and Accessories
The relay is available for networks with or without neutral conductor, with variant BA9043/002 specifically designed for systems with neutral conductor. It is available for nominal voltages from 3/N AC 100/57 V to 690/400 V. Devices are designed for use in enclosures and can be mounted on DIN rail. Connection terminals are rated for 2 x 2.5 mm² rigid or 2 x 1.5 mm² flexible conductors with heat-shrink tubing. Mounting is done using M3.5 plus-minus screws with self-locking clip, with a torque of 0.8 Nm.
Mounting and Installation
Mounting is done on DIN rail according to IEC/EN 60715. Connection terminals are designed for connection with rigid or flexible conductors. Dimensions are 45 mm (width) x 73 mm (height) x 132 mm (depth). Terminal markings include connections L1, L2, L3 and N for the network to be monitored, as well as contacts 11, 12, 14 and 21, 22, 24 for the output relays. Wiring requires no additional wiring effort, as no auxiliary voltage is required.
Operational Advantages
The BA9043/002 enables preventive maintenance through early detection of voltage anomalies. Rapid fault localization reduces downtime. LED indicators provide a visual status overview. Harmonic immunity ensures reliable operation even in networks with harmonic distortions. Adjustable time delay prevents unwanted disconnections during short-term voltage dips. Simple operation via rotary potentiometers reduces setup time and minimizes configuration errors. The device is suitable for industrial and railway applications and complies with UKCA and CCC certifications.