Dold 0028191, EAN: 4030641281915

Dold 0028191 voltage relay BA9036/012AC50HZ230V0,5-10S

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0028191 voltage relay BA9036/012AC50HZ230V0,5-10S

Lieske Part No. 624867
Mfg Part No 0028191
EAN-Code 4030641281915
Manufacturer Dold
Here only 278,51 EUR
331,43 EUR incl. VAT

Further information for Dold 0028191 voltage relay BA9036/012AC50HZ230V0,5-10S

Technical data
1- / 3-phase1
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.AC 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9036
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltageAC 230 V 50 Hz
Time delay0,5 - 10 s
Approvals and MarkingsCCC
VariantUndervoltage relay. Closed circuit operation. With time delay
The voltage relay BA9036/012AC50HZ230V0,5-10S from Dold is an undervoltage relay for monitoring single-phase DC or AC power networks. It is designed for continuous monitoring of operating voltage and reacts to deviations from the set nominal value to prevent damage to electrical installations. The device operates on the standby current principle, where the contacts are closed during normal operation and open in case of undervoltage. Adjustment is performed via rotary switches on the front of the device, enabling user-friendly and precise setting of pickup and drop-out values. The time delay is adjustable in the range of 0.5 to 10 seconds, allowing differentiated response to short-term voltage fluctuations. The relay is designed for use in enclosures and has a width of 45 mm, enabling compact mounting in standard control panels.

Applications
This relay is suitable for monitoring voltages in the range of 24 to 400 V AC/DC, with the nominal voltage for this variant being AC 230 V at 50 Hz. It is used in industrial plants, machine controls, or building automation where reliable voltage monitoring is required. The single-phase design makes it particularly suitable for applications with single-phase power supply. The pickup time delay ensures that short-term voltage dips do not cause unwanted shutdowns, thereby increasing operational safety.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, which can be used to control auxiliary functions or alarms. The contacts are rated for a thermal current of 6 A and have switching capacity according to AC 15 (make: 2 A / AC 230 V, break: 1 A / AC 230 V) and DC 13 (make: 1 A / DC 24 V, break: 1 A / DC 24 V). The electrical life expectancy is 150,000 switching operations at 6 A and AC 230 V, while the mechanical life expectancy is 30 million switching operations. The LED indicators signal operational readiness (upper LED) and activation of the output relay (lower LED), enabling quick visual inspection of the operating status.

Technology Explained Simply
The relay monitors the applied voltage and compares it with the set pickup value. In case of undervoltage below the set value (at least 0.6 times the nominal voltage), the time delay is activated, and after the set time has elapsed, the contacts open. The drop-out values range from 0.75 to 0.95 of the set value, ensuring hysteresis to prevent continuous switching on and off during voltage fluctuations around the threshold. The nominal frequency is 50 Hz, with a frequency tolerance of ±5 %. The temperature dependence of the measurement value is < 0.05 %/K, ensuring stable operation over a wide temperature range (−20 °C to +60 °C).

Compatibility and Accessories
The relay is designed for use without auxiliary voltage, simplifying installation. For DC voltages above 60 V, an external series resistor is required, connected to terminals e and z. The measured voltage is connected to terminals e and f. The required series resistors are available as accessories, e.g. ZWS 20 SL 1.5 kΩ 20 W for DC 110 V. The devices comply with the standard IEC/EN 60255-1 and are certified with CCC.

Mounting and Installation
The device is mounted in enclosures and is designed for mounting on standard 35 mm rails. Connections are made via terminals suitable for connecting wires. The LED indicators allow visual monitoring of operating states. Mounting is done without additional auxiliary voltage, making installation simple and cost-efficient.

Operational Advantages
Early detection of voltage drops and the possibility of preventive maintenance increase operational safety. The adjustable time delay prevents unnecessary shutdowns during short-term disturbances. The clear visual indication of operating states via LEDs simplifies diagnosis and maintenance. The high mechanical and electrical life expectancy ensures reliable long-term use in industrial environments.