Dold 0027221 under-voltage relay BA9043/003 3AC50/60Hz

Industrial Material > Industrial relays and contactors > Switching units / measuring, control relay

Dold 0027221 under-voltage relay BA9043/003 3AC50/60Hz

Lieske Part No. 156694
Mfg Part No 0027221
EAN-Code 4030641272210
Manufacturer Dold
Here only 302,01 EUR
359,39 EUR incl. VAT

Further information for Dold 0027221 under-voltage relay BA9043/003 3AC50/60Hz

Technical data
1- / 3-phase3
Auxiliary voltageWithout
Enclosure designSwitch cabinet
Nominal voltage max.3/N AC 690 / 400 V
Output contacts2 C/O contacts
Width45 mm
TypeBA 9043
Operate delayYes
Variant
Contact equipping2 changeover contacts
Nominal voltage3AC 500 V
Time delay0,5 - 10 s
Approvals and MarkingsUKCA
VariantFor 3p3w systems. With adjustable time delay
The undervoltage relay BA9043/003 from Dold is a 3-phase monitoring device for three-phase AC networks without a neutral conductor. It is designed for continuous monitoring of the supply voltage and disconnects connected loads in case of undervoltage or voltage loss to prevent damage to electrical equipment. The device is rated for nominal voltages of 3AC 500 V and is suitable for networks with frequencies between 50 and 400 Hz. Measurement is performed using an arithmetic mean value measurement, where phases L1 and L2 are measured against L3, as no neutral conductor connection is available. The setting of pickup and dropout values is done via rotary potentiometers on the front of the device, enabling user-friendly and precise adjustment for each specific application.

Applications
This relay is designed for use in industrial and railway applications, where reliable voltage monitoring is critical. It is mounted in enclosures and designed for continuous operation. The operating temperature range is between -20 °C and +60 °C, and the storage temperature range is between -25 °C and +60 °C. The maximum operating altitude is 2000 m above sea level. The devices comply with IEC/EN 60255-1 and carry the UKCA mark, confirming conformity with European safety requirements.

Functions and Equipment in Detail
The device features 2 changeover contacts as output contacts, rated for switching operations with a thermal current of up to 6 A per contact. Switching capacities are 2 A / AC 230 V for make contacts and 1 A / AC 230 V for break contacts according to AC 15 (IEC/EN 60947-5-1). The electrical life expectancy is at least 200,000 switching operations at 3 A and AC 230 V, while the mechanical life expectancy exceeds 30 million switching operations. The contacts are equipped with LED indicators for operational readiness (red LED) and contact position (green LED), allowing visual inspection of the operating status. The device operates on the standby current principle, where the output relay is not activated in the event of a fault, ensuring safe disconnection.

Technology Explained Simply
Voltage monitoring is performed by measuring individual phases against the third phase, as no neutral conductor is present. The pickup values are continuously adjustable between 0.85 and 1.05 times the nominal voltage, and the hysteresis (dropout ratio) ranges between 0.75 and 0.95 of the pickup value. The time delay is continuously adjustable from 0.5 to 10 seconds and only applies if the voltage is at least 0.6 times the nominal voltage. Below 0.4 times the nominal voltage, disconnection occurs immediately. The overload capacity is 1.2 times the nominal voltage continuously.

Compatibility and Accessories
The relay is designed for 3-phase AC networks without a neutral conductor. It is compatible with other variants of the BA 9043 series, such as BA9043/001 (without neutral conductor, without time delay) or BA9043/002 (with neutral conductor, with time delay). The devices are intended for mounting on a DIN rail (IEC/EN 60715). The terminal connections are rated for 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded), with a stripping length of 10 mm and a tightening torque of 0.8 Nm. Mounting is done using plus-minus screws with a self-releasing clamp lever.

Mounting and Installation
Mounting is done on a DIN rail inside the enclosure. Wiring is simple, as no auxiliary voltage is required. The terminal connections are clearly labeled: L1, L2, L3 for the supply lines and 11, 12, 14 as well as 21, 22, 24 for the two changeover contacts. Adjustment of pickup and dropout values and time delay is done via the rotary potentiometers on the front of the device. The width is 45 mm, and the dimensions are 45 x 73 x 132 mm (width x height x depth). The devices are insensitive to harmonics, making them suitable for networks with high harmonic content.

Operational Advantages
The relay enables preventive maintenance through early detection of voltage anomalies. Faster fault localization reduces downtime and increases productivity. The LED indicators provide visual feedback on the operating status. The adjustable time delay prevents unnecessary disconnections during short-term voltage dips. The high mechanical and electrical life expectancy ensures long service life with minimal maintenance. Energy efficiency is supported by the low nominal consumption of 4 VA (AC). The devices are EMC-compliant and feature an overvoltage category III with a rated impulse withstand voltage of 6 kV.

Approvals and Markings
The device carries the UKCA mark and complies with the standard IEC/EN 60255-1. EMC requirements are met according to IEC/EN 61000-4-2 (ESD), -4-3 (RF radiation), -4-4 (fast transients), and -4-5 (surge voltages). The devices are suitable for use in industrial and railway applications and comply with the requirements of DIN EN 50155 (for railway applications) as well as vibration and shock resistance according to Category 1, Class B (IEC/EN 61373).