| Technical data |
| 1- / 3-phase | 3 |
| Enclosure design | Switch cabinet |
| Measuring range max. | 500 V |
| Output contacts | 2 C/O contacts |
| Standard measuring range | 3 AC 400 V |
| Width | 45 mm |
| Type | BA 9041 |
| Variant |
| Contact equipping | 2 changeover contacts |
| Nominal voltage | 3AC 380 V 50 HZ |
The phase sequence relay BA 9041 from Dold monitors the correct phase sequence L1 - L2 - L3 as well as the presence of all three phase voltages in a three-phase power network. It prevents incorrect rotation directions in connected drives, especially in motors that require a specific phase sequence. The device is designed for use in enclosures and offers a width of 45 mm, enabling compact mounting in standard control panels. The rated voltage is 3AC 380 V at 50 Hz, and the device can also be operated with voltages between 220 V and 500 V within a range of 0.8 to 1.1 times the rated voltage.
Applications
This relay is used in industrial plants where correct phase sequence is critical for the safe operation of three-phase motors. It is particularly suitable for installations with thyristor controls, where commutation peaks or high harmonic content may cause false alarms. In such cases, it is recommended to test the device in the actual installation before final installation, to verify its functionality under specific network conditions.
Functions and Equipment in Detail
The device features two changeover contacts (11-14 and 21-24), which switch to the operating position when the correct phase sequence is present and all three phase voltages are applied. A green LED indicates correct operation. If the voltage in any phase drops below 60 % of the rated voltage, the relay is de-energized. For reverse voltages exceeding 60 % of the rated voltage, no fault signal is generated, as these may be caused by connected loads. In such cases, it is recommended to use an asymmetry relay (e.g. BA 9040).
Technology Explained Simply
The output contacts are designed as changeover contacts, meaning they switch between two positions depending on the operating state. The response time is less than 100 ms, and the reset time is less than 50 ms. The device is designed for continuous operation and consumes less than 3.5 VA. The thermal current rating is 5 A, and the switching capacity complies with IEC/EN 60947-5-1, with 2 A/AC 230 V for closing contacts and 1 A/AC 230 V for opening contacts. The electrical life is 250,000 switching operations at 3 A/AC 230 V, and the mechanical life is at least 50 million switching operations.
Compatibility and Accessories
The relay is suitable for networks with overvoltage category III up to 3 AC 480 V and category II for 3 AC 500 V. It complies with IEC/EN 60255-1 and is designed for operation in environments with temperatures from -20 °C to +60 °C. The maximum operating altitude is limited to 2000 m above sea level. The enclosure protection rating is IP 40, and the terminals have IP 20. The connection terminals are designed for 2 x 2.5 mm² single or 2 x 1.5 mm² stranded cable with heat-shrink tubing according to DIN 46228. Mounting is on a DIN rail according to IEC/EN 60715.
Mounting and Installation
Mounting is on a DIN rail inside the enclosure. Cable connections are made via flat terminals with self-lifting clamping elements. The specified tightening torque is 0.8 Nm. The dimensions of the device are 45 mm (width) x 73.2 mm (height) x 119.8 mm (depth). Terminal marking follows EN 50005.
Operational Advantages
By monitoring the phase sequence, the correct rotation direction of drives is ensured, which is particularly important for pumps, fans, and conveying systems. Simple wiring and clear indication via the LED facilitate commissioning and maintenance. The high mechanical and electrical life ensures reliable long-term use in industrial environments. Compliance with IEC/EN 60255-1 guarantees conformity with international standards for measuring and monitoring devices.
Additional Technical Specifications
The device is designed for operation in environments with creepage and clearance distances according to IEC 60664-1. The rated impulse voltage is 4 kV at pollution degree 2. EMC requirements comply with IEC/EN 61000-4-2 to -4-6, including immunity to electrostatic discharge (8 kV), high-frequency radiation (10 V/m), and fast transients (2 kV). Radio frequency interference suppression meets Class B limits according to EN 55011. Vibration resistance is tested for an amplitude of 0.35 mm and frequencies from 10 to 55 Hz according to IEC/EN 60068-2-6. Climatic resistance corresponds to test 20 / 060 / 04 according to IEC/EN 60068-1.