Dold 0023180, EAN: 4030641231804

Dold 0023180 IK8808 0,06-160S time relay delayed-answering

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0023180 IK8808 0,06-160S time relay delayed-answering

Lieske Part No. 271118
Mfg Part No 0023180
EAN-Code 4030641231804
Manufacturer Dold
Here only 121,63 EUR
144,74 EUR incl. VAT

Further information for Dold 0023180 IK8808 0,06-160S time relay delayed-answering

Technical data
Enclosure designDistribution board
Output contacts1 Thyristor
Time function(s)On-delay
Width17,5 mm
TypeIK 8808
Variant
Nominal voltageAC/DC 24 - 240 V
Time range0,06 - 160 s
Variant4 time ranges and 2 voltage ranges programmable via terminals
The Dold IK8808 0,06-160S is a delayed-on time relay for use in industrial control systems, particularly in two-wire technology. It is used for time-controlled switching of loads, where the output is activated only after a pre-set delay time. The device is designed in accordance with the EN 61812-1 standard and offers a programmable rated voltage as well as multiple time ranges, which can be configured via terminals. The width of 17.5 mm allows for compact mounting in standard installation distributor enclosures.

Applications
This time relay is suitable for applications requiring a delayed switching function, for example in automation technology, pump control systems, lighting installations, or production control. The delayed-on function ensures that the load is only activated after the set time has elapsed, which is necessary in many industrial processes to avoid inrush currents or to synchronize sequences.

Functions and Equipment in Detail
The device features a thyristor output, designed for load currents between 10 mA and 800 mA. The repeatability is ≤ ± 1 %, ensuring high precision in repeated switching operations. The time ranges are continuously adjustable on a relative scale and cover four different intervals: 0.06 to 0.6 s, 0.25 to 2.5 s, 2 to 20 s, and 16 to 160 s. The rated voltage is programmable and includes two ranges: AC/DC 24–60 V and AC/DC 60–240 V. Adjustment is done via terminals, allowing flexible adaptation to different operating voltages.

Technology Explained Simply
The delayed-on function means that the relay only switches the output after the set time has elapsed. This is achieved through an integrated timing control using an electronic timer. The thyristor technology enables controlled current transmission, which is particularly suitable for loads with high inrush currents. The two-wire technology allows for simple installation, as only two wires are required for power supply and control. The reset time is maximum 100 ms at 50 % and 25 ms at 100 % of the scale duration, enabling quick reset after switching off.

Compatibility and Accessories
The device is designed for use in standard installation distributor enclosures and can be mounted on a DIN rail. The terminals are rated for conductor cross-sections of 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded wire with sleeve DIN 46228). The voltage ranges and time ranges are programmable via terminals, allowing flexible adaptation to various applications. No special accessories are required, as all necessary functions are integrated into the device.

Mounting and Installation
Mounting is done via a DIN rail (IEC/EN 60715), enabling quick and secure fixation in standard switch enclosures. The connections are designed to be reverse-polarity protected, preventing incorrect wiring. The device must not be connected to voltage without a load, as this may cause damage to the relay. Connection examples in the data sheet show the correct wiring for various applications.

Advantages in Operation
The high repeatability and continuous adjustability of the delay time ensure reliable and precise switching operations. The programmable voltage and time ranges increase the flexibility of the device, allowing it to be used in various installations. The compact design with a width of 17.5 mm enables dense mounting in switch enclosures. The operating temperature ranges from -20 °C to +60 °C, ensuring broad applicability in different environments. The protection rating IP 40 for the housing and IP 20 for the terminals protects against mechanical impacts and contact, but not against splashing water or dust. EMC testing in accordance with IEC/EN 61000-4-2, -4-4 and -4-5 ensures robust operation in electromagnetically disturbed environments.

Functions and Equipment in Detail
The device features a thyristor output, designed for load currents between 10 mA and 800 mA. The repeatability is ≤ ± 1 %, ensuring high precision in repeated switching operations. The time ranges are continuously adjustable on a relative scale and cover four different intervals: 0.06 to 0.6 s, 0.25 to 2.5 s, 2 to 20 s, and 16 to 160 s. The rated voltage is programmable and includes two ranges: AC/DC 24–60 V and AC/DC 60–240 V. Adjustment is done via terminals, allowing flexible adaptation to different operating voltages.

Technology Explained Simply
The delayed-on function means that the relay only switches the output after the set time has elapsed. This is achieved through an integrated timing control using an electronic timer. The thyristor technology enables controlled current transmission, which is particularly suitable for loads with high inrush currents. The two-wire technology allows for simple installation, as only two wires are required for power supply and control. The reset time is maximum 100 ms at 50 % and 25 ms at 100 % of the scale duration, enabling quick reset after switching off.

Compatibility and Accessories
The device is designed for use in standard installation distributor enclosures and can be mounted on a DIN rail. The terminals are rated for conductor cross-sections of 2 x 2.5 mm² (solid) or 2 x 1.5 mm² (stranded wire with sleeve DIN 46228). The voltage ranges and time ranges are programmable via terminals, allowing flexible adaptation to various applications. No special accessories are required, as all necessary functions are integrated into the device.

Mounting and Installation
Mounting is done via a DIN rail (IEC/EN 60715), enabling quick and secure fixation in standard switch enclosures. The connections are designed to be reverse-polarity protected, preventing incorrect wiring. The device must not be connected to voltage without a load, as this may cause damage to the relay. Connection examples in the data sheet show the correct wiring for various applications.

Advantages in Operation
The high repeatability and continuous adjustability of the delay time ensure reliable and precise switching operations. The programmable voltage and time ranges increase the flexibility of the device, allowing it to be used in various installations. The compact design with a width of 17.5 mm enables dense mounting in switch enclosures. The operating temperature ranges from -20 °C to +60 °C, ensuring broad applicability in different environments. The protection rating IP 40 for the housing and IP 20 for the terminals protects against mechanical impacts and contact, but not against splashing water or dust. EMC testing in accordance with IEC/EN 61000-4-2, -4-4 and -4-5 ensures robust operation in electromagnetically disturbed environments.