Dold 0008808, EAN: 4030641088088

Dold 0008808 time relay delayed pickup 230V

Industrial Material > Industrial relays and contactors > Industrial Timers

Dold 0008808 time relay delayed pickup 230V

Lieske Part No. 1313005
Mfg Part No 0008808
EAN-Code 4030641088088
Manufacturer Dold
Here only 322,54 EUR
383,82 EUR incl. VAT

Further information for Dold 0008808 time relay delayed pickup 230V

Technical data
Enclosure designSwitch cabinet
Output contacts1 C/O contact
Time function(s)On-delay
Width45 mm
TypeAA 7616
Variant
Contact equipping1 NC contact delayed, 1 NC contact undelayed, 1 NO contact delayed, 1 NO contact undelayed
Nominal voltageAC 230 V
Time range0,2 s - 60 h
VariantNo-voltage safe
The Dold time relay AA7616.24/100 is a delayed-actuation relay for use in enclosures, designed for time-controlled operation of system components such as motors or pumps. It features a rated voltage of AC 230 V and a time range from 0.2 seconds to 60 hours, making it suitable for a wide range of applications in industrial automation. The width is 45 mm, enabling compact installation in standard control panels. The device is specified according to EN 61812-1 and offers a repeatability of ≤ ± 0.5 %, with a deviation of ≤ ± 1 % in the range of 3 and 6 seconds. The time function operates purely mechanically, ensuring high reliability and low maintenance requirements.

Applications
This time relay is used to implement time-delayed switching operations in industrial control systems. Typical applications include gradual motor start-up, delay in pump control systems, or synchronization of process steps in manufacturing plants. The ability to adjust the delay time continuously over a wide range allows for individual adaptation to specific requirements.

Functions and Equipment in Detail
The device features contact configuration with one delayed normally open contact, one instantaneous normally open contact, one delayed normally closed contact, and one instantaneous normally closed contact, forming a total of one changeover contact. The delayed contacts switch only after the set time has elapsed, while the instantaneous contacts react immediately. The time progression is indicated by a red pointer on the device scale, visually displaying the progress of the delay time. A switching position indicator is also integrated, although it is not present in the EH 7616 variant. The zero-voltage protection ensures that the elapsed time is retained in case of power failure, allowing the delay to continue once power is restored.

Technology Explained Simply
The time control is based on a purely mechanical principle, where a synchronous motor achieves the time delay via a gear train and coupling. The frequency switching between 50 Hz and 60 Hz is performed on the rear side of the device by moving a latch with a screwdriver. The delay time is adjusted via a continuously variable rotary switch on the front, allowing the user to precisely set the time within the range of 0.2 s to 60 h. The time ranges are divided into six switchable steps, which can also be selected from the front.

Compatibility and Accessories
The time relay is designed for use in enclosures and can be mounted in standard control panels with a width of 45 mm. It is equipped with zero-voltage protection, which retains the elapsed time in case of power failure. Terminal markings follow the standard: A1-A2 for control and operating voltage, B1-B2 for control voltage (in versions with B1-B2), and contact terminals 15-16 (delayed normally open), 27-28 (delayed normally closed), 31-32 (instantaneous normally open), and 43-44 (instantaneous normally closed). The use of quick start (for short times) requires the AA 7616.32 version, where terminals A1-A2 remain permanently connected to rated voltage.

Mounting and Installation
Mounting is performed in an enclosure using screw fastening. The front of the device is designed for operation, with the time delay adjusted via the rotary switch. Frequency switching is done on the rear side. The connection terminals are clearly labeled, ensuring correct wiring. The width of 45 mm allows for compact placement in existing control systems.

Advantages in Operation
The purely mechanical time control offers high operational reliability and is independent of electronic components. The continuous adjustment of the delay time over a wide range enables flexible adaptation to different requirements. The zero-voltage protection ensures that the time delay is not reset during short power interruptions, enhancing process safety. The visual indication of time progression facilitates monitoring and maintenance of the device during operation.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1313005
qrcode für Dold 0008808 time relay delayed pickup 230V