| Technical data |
| 1- / 3-phase | 1 |
| Auxiliary voltage | Without |
| Enclosure design | Switch cabinet |
| Output contacts | 1 C/O contact |
| Width | 45 mm |
| Type | AI 838 |
| Variant |
| Contact equipping | 1 changeover contact |
| Measuring range | DC 2,5 - 5 A RW48% |
The Dold overcurrent relay AI 838 DC2,5-5A RW48% is a single-phase measuring relay for monitoring direct current circuits in the range of 2.5 to 5 amperes. It is used for electrical protection and control in industrial installations where precise current monitoring is required. The device is designed for use in enclosures and has a width of 45 mm, enabling compact mounting in standard switchboards. The relay scale is adjusted to the pickup value, so the relay activates when the set current value is exceeded. Resetting occurs when the current falls below the drop-out value, which is calculated by multiplying the pickup value by the drop-out ratio (RW48%).
Applications
The AI 838 is used in installations where monitoring of direct current lines is necessary, for example in battery systems, emergency power supplies, or industrial controls. It is particularly suitable for applications requiring high accuracy in current measurement and reliable response to overloads. The direct measurement in the range of 2.5 to 5 A without auxiliary voltage makes it independent of additional power sources and thus robust under critical operating conditions.
Functions and equipment in detail
The relay features a single changeover contact as output contact, which changes its state when the relay operates. The pickup value is adjusted continuously and internally within the device, enabling precise adaptation to the specific application. The drop-out ratios for direct current with a residual ripple of 48 % are approximately 0.8 at the beginning of the scale and approximately 0.9 at the end of the scale. The repeatability accuracy for direct current is ≤ 15 %, ensuring high reproducibility of the measured values.
Technology explained simply
The relay operates without auxiliary voltage, meaning it is powered directly from the circuit being monitored. The internal resistance of the relay in the measuring range of 2.5–5 A is approximately 0.166 Ohm, ensuring minimal impact on the monitored circuit. The switching delay is approximately 100 ms, preventing short current surges from causing unwanted tripping. The electrical life is 5 million switching operations at a load of 30 % of switching capacity, ensuring high operational reliability over a long period.
Compatibility and accessories
The AI 838 is designed for use in single-phase direct current installations. For higher currents above 16 A, the measuring range can be extended by paralleling a shunt, with the data sheet referring to a connection lead with a resistance of approximately 0.5 mΩ at 20 °C. The use of current transformers is intended for alternating current applications, but not for the direct current range specified here.
Mounting and installation
The relay is mounted in enclosures and is designed for mounting on standard 35 mm rails. The connection terminals are intended for direct connection to the lines being monitored. Mounting requires no additional tools, as the width of 45 mm fits standard switchboards. The pickup value is adjusted via a rotary knob on the front of the device.
Advantages in operation
The AI 838 provides reliable current monitoring without auxiliary voltage, simplifying installation and increasing operational safety. The continuous adjustment of the pickup value allows precise adaptation to the specific application. The high electrical life and low switching delay ensure stable and responsive operation. Compliance with the standard IEC/EN 60255-1 ensures adherence to international standards for electrical measuring instruments.