DEHN 952206, EAN: 4013364123922

DEHN 952206 surge arrester Type2 guard M 1ph TN

DEHN 952206 surge arrester Type2 guard M 1ph TN

Lieske Part No. 1285141
Mfg Part No 952206
EAN-Code 4013364123922
Manufacturer DEHN
Here only 245,38 EUR
292,00 EUR incl. VAT

Further information for DEHN 952206 surge arrester Type2 guard M 1ph TN

Standards
CertificationUL
UL StandardUL 1449 5th edition
UL File NumberE319777
Technical data
Energy coordination with terminal equipment (≤ 10 m)type 2 + type 3
Nominal voltage (a.c.) (UN)120 V (50 / 60 Hz)
Max. continuous operating voltage (AC) (UC)150 V (50 / 60 Hz)
Nominal discharge current (8/20 µs) (In)15 kA
Max. discharge current (8/20 µs) (Imax)40 kA
Voltage protection level [L-PE]/[N-PE] (UP)≤ 0.8 / ≤ 0.8 kV
Voltage protection level [L-PE]/[N-PE] at 5 kA (UP)≤ 0.55 / ≤ 0.55 kV
Response time (tA)≤ 25 ns
Max. mains-side overcurrent protection125 A gG
Short-circuit withstand capability for max. mains-side overcurrent protection (ISCCR)50 kArms
Temporary overvoltage (UT) – characteristic175 V / 5 sec. – Festigkeit, 230 V / 120 min. – sicherer Ausfall
Operating temperature range (TU)-40 °C ... +80 °C
Operating state / fault indicationgreen / red
Number of ports1
Cross-sectional area (min.)1.5 mm2 solid / flexible
Cross-sectional area (max.)35 mm2 stranded / 25 mm2 flexible
For mounting on35 mm DIN rails acc. to EN 60715
Enclosure materialthermoplastic, red, UL 94 V-0
Place of installationindoor installation
Degree of protectionIP 20 (integrated)
Capacity2 Standard DIN module, DIN 43880
ApprovalsDEKRA, UL
Type of remote signalling contactchangeover contact
Switching capacity (a.c.)250 V / 0.5 A
Switching capacity (d.c.)250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
Cross-sectional area for remote signalling terminalsmax. 1.5 mm2 solid / flexible
Test values according to UL 1449
ModeL-N/L-G/N-G
Rated Voltage (AC, 50/60 Hz)120 V
MCOV (AC, 50/60 Hz) [L-N]/[L-G]/[N-G]150 V
MLV (AC, 50/60 Hz) [L-N]/[L-G]/[N-G]1410/1180/1180 V
Nominal discharge current (8/20µs) ( In)20 kA
Maximum ambient temperature+85 °C
AWG (conductors)4-14 Cu solid/stranded
AWG (remote indicator)14-22 Cu
UL 1449 edition5th edition
Type (SPD classification)Type 4 component assembly
Multipole surge arrester DEHNguard M, type 2 according to EN 61643-11, consisting of a base part and plugged-in protection modules. High device safety due to arrester monitoring with thermo-dynamic control. For protecting low-voltage consumer systems against surges. For use in the lightning protection zone concept at the interfaces 0B - 1 and higher.