General
Degree of protectionType 1 + Type 2 in accordance with EN 61643-11
Technologyspark gap base
Follow-up current limitationRADAX-Flow
Applicationlow-voltage consumer installations
Insert interfaces0A - 2 Lightning protection zone concept
System typeTN-S systems
ModularityBase unit with inserted protection modules
The DEHNventil modular, type DV M TNS 255 FM, is a multipole combination surge arrester for low-voltage consumer installations, developed for protection against overvoltages, including direct lightning strikes. The device is based on spark gap technology and complies with the requirements of standard EN 61643-11 for Type 1 and Type 2. It consists of a base unit into which protection modules are inserted, enabling a modular and adaptable protection configuration. The application is carried out within the lightning protection zone concept at interfaces 0A to 2, ensuring integration into the overall protection strategy for buildings and technical installations.

Applications

The combination surge arrester is designed for use in TN-S systems, which are commonly used in electrical engineering for supplying consumers in buildings and industrial facilities. It protects electrical installations and end devices against transient overvoltages caused by atmospheric discharges or switching operations in the network. The suitability for interfaces 0A to 2 makes it particularly suitable for use at the entry interface of an installation, where the highest overvoltage stress is expected.

Functions and Equipment in Detail

The device combines the protective functions of Type 1 and Type 2 in a single component, resulting in a compact and efficient solution. The RADAX-Flow follow-current limitation ensures that after an overvoltage impulse, the follow current is quickly reduced, increasing the availability of the installation and minimizing damage to downstream equipment. The modular design allows flexible adaptation to different installation configurations, with individual protection modules inserted into the base unit.

Technology Explained Simply

The operation is based on spark gaps, which are bridged during overvoltage to divert the overvoltage current. The RADAX-Flow technology reduces the residual current that may continue to flow after the impulse, thereby reducing the load on the installation. The protection modules are designed for specific conductors (e.g., phase, neutral conductor) and are inserted into the base unit, enabling individual configuration. Standard EN 61643-11 defines the requirements for surge protection devices, with Type 1 intended for direct lightning strikes and Type 2 for indirect overvoltages.

The application occurs at interfaces 0A to 2 of the lightning protection zone concept, meaning the device is installed at the entry interface of the installation to protect the entire downstream electrical installation. The modular design allows flexible adaptation to the specific installation, with protection modules being exchangeable or expandable according to requirements.

Compatibility and Accessories

The combination surge arrester is designed for TN-S systems, which are typically used in buildings with separate neutral and protective conductors. The modular design allows combination with additional protection modules specifically designed for the respective installation. Use in conjunction with other DEHN products that also follow the lightning protection zone concept is possible to ensure a consistent protection strategy.

Mounting and Installation

Installation takes place at the entry interface of the electrical installation, in accordance with the requirements of the lightning protection zone concept. The base unit is installed in the distribution unit, with protection modules inserted according to the conductor configuration (e.g., 3-phase system). Mounting requires compliance with electrical standards and adherence to safety regulations when handling high voltage.

Advantages in Operation

By combining Type 1 and Type 2 protection in a single device, a compact and efficient protection solution is achieved. The RADAX-Flow follow-current limitation increases the availability of the installation, as the follow current is quickly reduced. The modular design allows flexible adaptation to different installation configurations, simplifying maintenance and expansion of the protection system. Compliance with standard EN 61643-11 ensures reliability and safety of the device in practice.