| General |
| Protection type | Type 1+2+3 |
| System type | TT and TN-S systems |
| Circuit | 3+1 circuit |
| Power supply | 230 V V |
| Protection function | overcurrent protected |
| Mounting technique | Click+Power connection technology |
| Grounding terminal | Push-in |
| Busbar system | 40 mm |
| Replacement fuse | for RfZ / APZ |
| Norm | DIN EN 61643-11 |
| Application | main power supply system |
| Application area | Buildings with overhead line feed-in |
| Accessories included in delivery | cover clip according to DIN VDE 0603-1, 2 x socket, 2 x plug |
| Wiring | for intelligent metering system according to VDE-AR 4100 |
| SPD according to EN 61643-11 / IEC 61643-11 | type 1 + type 2 + type 3 / class I + class II + class III |
| Energy coordination with terminal equipment (≤ 10 m) | type 1 + type 2 + type 3 |
| Nominal voltage (a.c.) (UN) | 230 / 400 V (50 / 60 Hz) |
| Max. continuous operating voltage (AC) (UC) | 255 V (50 / 60 Hz) |
| Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] (Itotal) | 30 kA |
| Lightning impulse current (10/350 µs) [L-N] (Iimp) | 7.5 kA |
| Specific energy [L-N] (W/R) | 14.06 kJ/Ohm |
| Lightning impulse current (10/350 µs) [N-PE] (Iimp) | 30 kA |
| Specific energy [N-PE] (W/R) | 225 kJ/Ohm |
| Nominal discharge current (8/20 µs) [L-N]/[N-PE] (In) | 20 / 80 kA |
| Voltage protection level [L-N] (UP) | ≤ 1.5 kV |
| Voltage protection level [N-PE] (UP) | ≤ 1.5 kV |
| Open-circuit voltage of the combination wave generator (UOC) | 20 kV |
| Max. mains-side overcurrent protection | 160 A gG |
| Temporary overvoltage (TOV) [L-N] (UT) – Characteristic | 440 V / 120 min. – withstand |
| Temporary overvoltage (TOV) [N-PE] (UT) - Characteristic | 1200 V / 200 ms – withstand |
| Operating temperature range (TU) | -40 °C ... +80 °C |
| Operating state / fault indication | green / red |
| Number of ports | 1 |
| Cross-sectional area (PEN, ) | 16-25 mm2 stranded, fine-stranded |
| For mounting on | 40 mm busbar systems |
| Enclosure material | thermoplastic, red, UL 94 V-0 |
| Place of installation | indoor installation |
| Degree of protection | IP 30 (in combination with cover) |
| Approvals | VDE |
| Power supply (for compartment for additional applications/termination point meter mounting board according to VDE-AR-N 4100) (UN) | 230 V |
| Rated current of the fuse link of the terminal device (class F) (In) | 6.3 A |
| Fuse link | SIBA GZ 6.3 x 32 mm F 500 |
| Extended technical data |
| Voltage protection level [L-PE] (UP) | ≤ 1.6 kV |
The DEHN DSH ZP B2 SG TT 255 is a certified combination surge arrester of types 1+2+3, designed for use in the main power supply system of buildings in accordance with DIN VDE 0100-443. It is specifically designed for TT- and TN-S systems with 3+1 configuration and provides comprehensive surge protection. The arrester integrates an overcurrent-protected 230 V power supply for lines N and L, with replacement fuses for RfZ and APZ according to VDE-AR-N 4100 provided. Installation is tool-free via the Click+Power connection technology, specifically designed for the 40 mm busbar system, and is supplemented by a Push-in earthing terminal, enabling quick and secure earthing.
Applications
This arrester is intended for use in buildings, particularly in systems with overhead line feed, even without an external lightning protection system. It protects the electrical installation against transient overvoltages caused by lightning strikes or switching operations in the network. The application is in the main power supply system, where high protection performance is required to secure the entire electrical installation.
Functions and Equipment in Detail
The combination arrester integrates the protection functions of types 1, 2, and 3 into a single device, creating a compact and efficient solution for surge protection systems. The integrated 230 V power supply for N and L enables supply of additional functions such as RfZ or APZ, with the overcurrent-protected design ensuring safe operation. The replacement fuses are directly integrated into the device, simplifying replacement in case of failure.
Technology Explained Simply
The Click+Power connection technology enables tool-free installation onto the 40 mm busbar system, allowing quick installation without additional tools. The Push-in earthing terminal ensures a reliable earthing connection, which is essential for the proper operation of the arrester. The protection functions of types 1+2+3 cover direct lightning strikes (type 1), overvoltages from the network (type 2), and local switching overvoltages (type 3).
Compatibility and Accessories
The arrester is designed for TT- and TN-S systems and adapts to common switchgear configurations. The delivery includes one cover clip according to DIN VDE 0603-1 for each standard metering field, as well as 2 x socket and 2 x plug, for wiring the intelligent metering system according to VDE-AR 4100. These components enable integration into modern metering systems without requiring additional connection cables.
Installation and Mounting
Installation is tool-free onto the 40 mm busbar system using the Click+Power technology. Earthing is achieved via the Push-in terminal, enabling quick and secure installation. The integrated replacement fuses for RfZ and APZ simplify replacement in case of failure. Wiring of the intelligent metering system is done using the included sockets and plugs.
Operational Advantages
The DEHN DSH ZP B2 SG TT 255 offers compact, tool-free mounting and integrated functions for supplying additional systems. The combination of protection types 1+2+3 in a single device reduces space requirements and simplifies planning of the surge protection system. The integrated replacement fuses for RfZ and APZ, along with tool-free mounting, increase operational safety and reduce installation time. Use in the main power supply system ensures comprehensive protection for the entire electrical installation.