| General |
| Norm | DIN EN 62561-1 |
| Connection type | Cross piece |
| Flat cable cross-section | 30 mm² |
| Screw size | M8 |
| Model | Without intermediate plate |
| Application range | above- and below-ground |
| Material of clamp | St/tZn |
| Clamping range Fl / Fl | 30 / 30 mm |
| Dimensions | 60 x 60 x 3 mm |
| Standard | EN 62561-1 |
| Short-circuit current (AC 50 Hz / DC) (1 s; ≤ 300 °C) | 8.4 kA |
The DEHN crosspiece type KS FL30 STTZN, manufacturer number 318033, is a connecting element for earthing and lightning protection systems. It is designed for the secure and permanent connection of two flat conductors with a cross-section of 30 mm², where the connection can be made both above and below ground. The product is manufactured in accordance with the standard DIN EN 62561-1, which defines requirements for lightning protection materials in earthing installations. The construction is without an intermediate plate, ensuring a direct mechanical and electrical connection between the conductors. The fastening is done using M8 screws, which provide a firm and corrosion-resistant connection.
Lightning protection material such as the DEHN crosspiece is used in electrical installations to ensure a reliable earthing circuit. Particularly in buildings with lightning protection systems or in industrial facilities where high electrical currents must be diverted, a stable connection between the conductors is essential. The crosspiece enables the branching or crossing of flat conductors without impairing electrical conductivity or mechanical strength. Use in underground installations requires high corrosion resistance, which is supported by the material selection and the design without an intermediate plate.
Functions and equipment in detail include the use of M8 screws for securing the flat conductors. These screws are designed for a secure mechanical connection and ensure low transition resistance values, which are crucial for the effectiveness of the earthing system. The design without an intermediate plate reduces the number of contact points and thus minimizes the risk of corrosion or contact degradation over time. The connection is made directly between the two flat conductors, achieving high electrical conductivity and mechanical stability.
Technology explained simply shows that the crosspiece serves as a mechanical and electrical transition. The standard DIN EN 62561-1 specifies that such components must meet certain requirements for electrical conductivity, mechanical strength, and corrosion resistance. The use of M8 screws enables precise and durable fastening, which remains stable even under stress from earthing currents or mechanical loads. The direct connection without an intermediate plate reduces the number of contact surfaces, lowering the likelihood of oxidation or contact resistance.
Compatibility and accessories refers to use with flat conductors having a cross-section of 30 mm². The crosspiece is specifically designed for this dimension and ensures a precise fit. It is intended for use in earthing installations executed in accordance with DIN EN 62561-1. Use in combination with other DEHN products, such as earthing rails or connecting elements, is possible as long as dimensions and standards are compatible.
Installation and mounting is done by attaching the two flat conductors to the designated mounting points on the crosspiece. The M8 screws are tightened using appropriate tools, with the specified torque value being observed to ensure an optimal connection. Installation can be carried out both outdoors and underground, taking into account environmental conditions such as humidity or ground load. After installation, the connection must be checked for mechanical stability and electrical conductivity.
Operational advantages lie in the high reliability and longevity of the connection. The design without an intermediate plate reduces the number of contact points, thereby minimizing the risk of corrosion or contact degradation. The use of M8 screws ensures a secure fastening that remains stable even under high electrical and mechanical loads. Compliance with DIN EN 62561-1 guarantees adherence to required safety and performance standards for lightning protection systems. The crosspiece is thus a reliable component for earthing installations in buildings, industrial facilities, or other applications where secure earthing is required.