Chauvin Arnoux P01120409, EAN: 3760171412909

Chauvin Arnoux P01120409 clamp MN60 CV for oscilloscopes

Measurement > Ammeters

Chauvin Arnoux P01120409 clamp MN60 CV for oscilloscopes

Lieske Part No. 777669
Mfg Part No P01120409
EAN-Code 3760171412909
Manufacturer Chauvin Arnoux
Here only 312,62 EUR
372,02 EUR incl. VAT

Further information for Chauvin Arnoux P01120409 clamp MN60 CV for oscilloscopes

General
Maximum AC measurement range240 A
Peak current measurement600 A
Bandwidth10 kHz
Output signalAlternating voltage
Output/input ratio100 mV / A AC, 10 mV / A AC
Outputcoaxial cable with insulated BNC connector
Insertion diameter20 mm
Application categoryCAT III 600 V, CAT IV 300 V
The MN60 clamp from Chauvin Arnoux is an insulated AC current transformer specifically designed for use with oscilloscopes. It enables the measurement of alternating currents up to 240 A when connected to multimeters or power analysers, and provides peak current display up to 600 A when connected to an oscilloscope. The compact and ergonomic design is intended for measurements in hard-to-reach locations, with the clamp capable of enclosing cables up to a maximum diameter of 20 mm. Applications are in electrical installations of category CAT III 600 V or CAT IV 300 V, ensuring safe measurement in industrial and commercial environments.

Applications

The MN60 is suitable for precise measurement of alternating currents in various technical applications, particularly in electrical engineering, for maintenance and servicing of machines and systems, as well as for analysing power consumption. The clamp is frequently used in industrial electrical engineering, for testing motors, transformers, and electrical circuits. The insulation of the current transformer protects the user and the measuring device from dangerous voltages, enabling safe measurement even in high-voltage environments.

Functions and Equipment in Detail

The clamp features two measurement ranges defined by the output/input ratio of 100 mV / A AC and 10 mV / A AC. This allows flexible adaptation to different measurement tasks, with the higher range suitable for smaller currents and the lower range for larger currents. The output signal is an alternating voltage transmitted to the measuring device via a coaxial cable with an insulated BNC connector. This construction ensures reliable and interference-free signal transmission, especially at high frequencies.

Technology Explained Simply

The current transformer operates on the principle of inductive current measurement: when a current-carrying conductor is passed through the clamp, the current generates a magnetic field that induces a voltage in the clamp. This induced voltage is proportional to the current in the conductor and is transmitted to the measuring device via the coaxial cable. The insulation of the transformer protects the measuring device and the user from dangerous voltages, as there is no galvanic connection between the object under test and the measuring device. The bandwidth of up to 10 kHz allows representation of rapid current changes, which is important for analysing transient events or diagnosing switching operations.

Compatibility and Accessories

The MN60 is primarily designed for use with oscilloscopes, but can also be operated with multimeters or power analysers. Connection is made via the insulated BNC connector, which is attached to the inputs of the mentioned devices. The clamp is not suitable for direct current measurements, as it only detects alternating currents. Compatibility with other measuring devices depends on their input characteristics, particularly the required impedance and maximum input voltage.

Installation and Mounting

Installation is carried out by simply clamping the conductor to be measured with the clamp. The clamp opening is designed for cables up to 20 mm in diameter, allowing even larger conductors to be measured. The clamp is not screwed or mounted, but positioned directly on the conductor. Measurement is performed without interrupting the circuit, enabling quick and safe testing. The insulation of the transformer ensures that no electrical connections exist between the object under test and the measuring device.

Advantages in Operation

The MN60 offers high measurement accuracy combined with safety due to galvanic isolation. The compact design and ergonomic shape facilitate handling, especially in tight or hard-to-reach areas. The use of two measurement ranges allows flexible adaptation to different current levels, making the clamp suitable for a wide range of applications. The bandwidth of 10 kHz enables capture of rapid current changes, which is beneficial for diagnosing electrical systems. The clamp is approved for use in installations up to CAT III 600 V or CAT IV 300 V, ensuring broad applicability in industrial and commercial environments.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/777669
qrcode für Chauvin Arnoux P01120409 clamp MN60 CV for oscilloscopes