| General |
| Application | Measurement of high DC currents with a voltmeter |
| Protection standard | IEC 61010, CAT III 600 V |
| Connection | Safety sockets |
| Housing | Shock-resistant and self-extinguishing |
| Accuracy class | 0,5 |
| Temperature coefficient | Very low |
| Nominal current | 30 A |
| Voltage drop | 300 mV |
The laboratory shunt from Chauvin Arnoux, type HA030-1, is a measuring shunt for precise and safe measurement of high direct currents (DC) in conjunction with a voltmeter. It serves as a resistance element connected in series with the circuit to be measured, creating a known voltage drop that can be measured with a voltmeter and converted into current. The design is specifically intended for use in laboratory environments and technical education, with safety and measurement accuracy being the primary focus.
Applications
The shunt is designed for measuring direct currents up to 30 A, with a voltage drop of 300 mV at rated current. This allows for use with standard voltmeters capable of accurately displaying small voltages. Applications include educational environments, testing of electrical devices, or laboratories where safe and reproducible current measurement is required. The protective insulation in accordance with IEC 61010, CAT III 600 V, makes it suitable for use in electrical installations with operating voltages up to 600 V.
Functions and Equipment in Detail
The shunt features safety sockets with a diameter of 4 mm, ensuring a secure and reliable connection. These sockets are designed to provide enhanced safety in case of incorrect handling or short-circuiting. The housing is impact-resistant and self-extinguishing, increasing operational safety in demanding work environments. The material selection ensures that the device does not easily ignite even under mechanical stress or in the event of a short circuit.
Technology Explained Simply
The shunt operates on the principle of a shunt: the current to be measured flows through the resistance, creating a voltage drop proportional to the current. This voltage drop is measured with a voltmeter, and the current can be calculated from the ratio of voltage to resistance. The accuracy class 0.5 means that the deviation of the measured value from the actual value is at most 0.5 %. The very low temperature coefficient ensures that resistance values remain stable even with temperature fluctuations, securing measurement accuracy over extended periods.
Compatibility and Accessories
The shunt is designed for use with voltmeters capable of accurately displaying voltages in the range of 300 mV. It is part of a range that also includes other rated currents such as 1 A, 5 A, 10 A, and 20 A. Use with other measuring instruments is possible, provided the voltage measurement can be performed within the range of the generated voltage drop. The safety sockets allow for easy and secure connection with standard test leads.
Mounting and Installation
Installation is carried out by directly connecting the shunt in series within the current circuit. The safety sockets allow for simple and secure connection with test leads. It is essential to ensure that the shunt is not overloaded, as this may lead to overheating or damage. Use in installations with operating voltages exceeding 600 V is not intended, as the protective insulation is certified only up to CAT III 600 V.
Advantages in Operation
The combination of high safety, precise measurement, and robust design makes the shunt a reliable tool in laboratory and educational environments. The accuracy class 0.5 and low temperature coefficient ensure reproducible measurement results. The impact-resistant and self-extinguishing housing increases service life and safety under mechanical stress or in the event of a short circuit. The protective insulation in accordance with IEC 61010, CAT III 600 V, enables use in electrical installations with operating voltages up to 600 V.