| Ports & interfaces |
| Input connection type | IEC 309 16A 3P+N+PE |
| Output connections | (1) IEC 309 16A |
| Power |
| Nominal input voltage | 400 V |
| Nominal output voltage | 400 V |
| Maximum input current per phase | 16 A |
| Maximum total current draw per phase | 16 A |
| Weight & dimensions |
| Weight | 1.39 kg |
The APC IT Power Distribution Module (type PDM3516IEC-140) is a modular power distribution component for use in data centres and IT infrastructures. It is designed for the safe and flexible distribution of electrical power within rack systems and is specifically designed for integration into power distribution units (PDU). The module features a three-phase, five-wire connection according to IEC 309 with a rated current of 16 A per phase and a rated voltage of 400 V. It is designed for operation in three-phase networks and enables the supply of devices with corresponding input power. The output side provides a single IEC 309 16A connection, also rated for 400 V. The maximum current draw per phase is 16 A, ensuring the module’s performance capacity for typical IT loads.
Applications
The module is primarily intended for use in data centres and server rooms, where flexible and secure power distribution is required. It is suitable for integration into vertical and horizontal rack distribution panels, with its modular design enabling easy adaptation to changing requirements. The pre-assembled version, including an integrated circuit breaker, power cable, and connection components, reduces installation time and minimises the need for additional mounting work. Automatic detection by the PDU supports quick commissioning without manual configuration.
Functions and Equipment in Detail
The module is equipped with an automatic circuit breaker that disconnects the circuit in case of overload or short circuit. The integrated power cable connection is 140 cm long and allows flexible positioning within the rack. The connectors are designed with form-fit features to prevent accidental disconnection of the plug connection. The contact points are insulated, enhancing user safety. The status indicator provides a quick overview of the module’s operating state. Current consumption measurement and monitoring are performed via integrated components for branch circuit monitoring and output measurement, which are included in the delivery scope.
Technology Explained Simply
The designation IEC 309 16A 3P+N+PE describes an industrial plug connector with three phase conductors (3P), one neutral conductor (N), and one protective earth conductor (PE), rated for a nominal voltage of 400 V and a nominal current of 16 A. The five-wire configuration ensures safe and reliable power supply, especially in environments with high electrical demands. The nominal voltage of 400 V is the standard voltage for three-phase networks in Europe and corresponds to the typical supply voltage in data centres. The maximum current draw of 16 A per phase corresponds to the module’s rated capacity and is sufficient for supplying servers, switches, and other IT devices.
Compatibility and Accessories
The module is designed for integration into APC and Schneider Electric PDUs, particularly in systems that support modular power distribution units. It is compatible with vertical and horizontal rack distribution panels. The use of matching power distribution modules with the same output voltage is required to ensure safe and proper installation. The modules can be installed without tools in less than ten minutes, with the pre-assembled version simplifying the mounting process.
Mounting and Installation
Installation is performed by inserting the module into the designated slot of the PDU. To do this, the slot lock must be removed using the included key, the filler plate removed, and the module inserted into the slot. The locking mechanism is then closed to securely connect the module to the busbar. The cables are routed through the upper opening in the housing and guided into the cable guides. Installation must be carried out by qualified personnel, with the power supply switched off and locked out before mounting. In systems with battery operation (e.g. Symmetra PX UPS), the UPS must be switched to battery mode to minimise fault currents.
Operational Advantages
The module offers high flexibility in power distribution, as it can be quickly exchanged or repositioned without tools. The integrated current monitoring enables precise measurement of power consumption, which is important for energy efficiency and load planning in data centres. The pre-assembled version reduces installation time and minimises error sources. The insulation of contact points and form-fit connectors enhance operational safety. Automatic detection by the PDU simplifies system administration and reduces effort during commissioning.