Further information for APC BV650I-GR UPS 650 VA AVR
Battery
Battery technology
Sealed Lead Acid (VRLA)
Battery capacity
7 Ah
Battery voltage
12 V
Battery recharge time
8 h
Cold start
Certificates
Compliance certificates
RoHS
Certification
CE
REACH
Design
Form factor
Compact
Cable length
1.52 m
Product colour
Black
LED indicators
Features
UPS topology
Line-Interactive
Output power capacity
0.65 kVA
Output power
375 W
Waveform
Sine
Input operation voltage (min)
170 V
Input operation voltage (max)
280 V
Input frequency
50/60 Hz
Output frequency
50/60 Hz
Surge energy rating
156 J
Transfer time (Line Mode to Battery Mode)
6 ms
Number of input phases
1
Number of output phases
1
Noise level
40 dB
Audible alarm modes
Alarm when on battery, Low battery alarm, Overload alarm
Automatic Voltage Regulation (AVR)
Surge protection
Audible alarm(s)
Logistics data
Harmonized System (HS) code
85078000
Operational conditions
Operating temperature (T-T)
0 - 40 °C
Operating relative humidity (H-H)
0 - 90%
Operating altitude
0 - 1968.3 m
Other features
Nominal output voltage
230 V
Packaging content
Management card included
Packaging data
Package width
373 mm
Package depth
143 mm
Package height
237 mm
Package weight
4.8 kg
Ports & interfaces
AC outlet types
Type F
AC outlets quantity
4 AC outlet(s)
SmartSlot
SmartConnect port
Weight & dimensions
Width
160 mm
Depth
305 mm
Height
92 mm
Weight
4.5 kg
The APC Easy UPS BV650I-GR is an uninterruptible power supply (UPS) in a compact design, intended for use in office environments and with IT end devices. The unit features an output capacity of 0.65 kVA and an output power of 375 W, with a nominal output voltage of 230 V. The UPS operates using the Line-Interactive topology, which enables automatic voltage regulation (AVR) to compensate for voltage fluctuations in the mains without drawing on the battery. This ensures stable power supply to connected devices as long as the input voltage remains within the range of 170 V to 280 V. In the event of voltage drops below 170 V or surges above 280 V, the UPS automatically switches to battery operation, with a transfer time from mains to battery of 6 ms. The output AC voltage has a sine wave form, suitable for sensitive electronic devices.
Applications
The UPS is designed for indoor use and is particularly suitable for protecting computers, network equipment, printers, and other sensitive IT end devices. Its compact design and black-painted front panel allow for discreet placement under desks or in server rooms. The operating temperature range is from 0 °C to 40 °C, with relative humidity up to 90 % during operation, making the device suitable for use in rooms with moderate environmental conditions. The maximum operating altitude is 1968.3 m, enabling use in mountainous regions.
Functions and Equipment in Detail
The unit features four AC outlets with Type F sockets (safety sockets), designed for both power supply and surge protection. The input power is supplied via a network cable with a length of 1.52 m. The battery technology is based on sealed lead-acid (VRLA) batteries with a voltage of 12 V and a capacity of 7 Ah. The battery recharge time is 8 hours, and charging can also occur when the device is switched off. A cold start is possible, allowing the device to be activated without mains connection, provided the battery is charged. The UPS includes LED indicators to visually signal the operating status, as well as acoustic alarms triggered during battery operation, low battery charge, or overload conditions.
Technology Explained Simply
The Line-Interactive topology combines the benefits of a pure UPS with efficient voltage regulation. In normal operation, the load is supplied directly from the mains, with the AVR function compensating for voltage fluctuations within the range of 170 V to 280 V. Only in the event of critical voltage drops or surges does the UPS switch to internal battery power, with a transfer time of 6 ms sufficient for most IT devices to maintain safe operation. The sine wave form of the output voltage is essential to ensure proper function of devices with electronic circuits, such as power supplies or motor controls. The noise level of 40 dB is acceptable for an office environment and contributes to a quiet operating atmosphere.
Compatibility and Accessories
The UPS is designed for use with IT end devices and network technology. The four safety sockets (Type F) allow compatibility with standard power devices in Europe. The UPS does not feature SmartSlot or SmartConnect interfaces, so additional management cards or network integration are not possible. The batteries are integrated into the device and can be replaced if necessary, with original manufacturer batteries recommended to ensure safety and performance. The use of replacement batteries requires compliance with safety regulations, particularly when handling lead-acid batteries.
Installation and Mounting
Installation is performed by directly connecting the power cable to a grounded socket. It is recommended to avoid operating the device through a surge protector or power strip, and instead connect it directly to a wall socket. The UPS should be placed in a location protected from direct sunlight, excessive heat, humidity, and dust. Connected devices should be plugged directly into the UPS outputs, avoiding the use of extension cords to ensure performance and safety. The device is activated after switching on via the ON/OFF switch, with the green LED Power On confirming operation.
Operational Advantages
The APC Easy UPS BV650I-GR provides reliable power supply for sensitive IT devices with clear, straightforward operation. The integrated AVR function ensures stable voltage without activating the battery, extending battery life. The short transfer time of 6 ms protects against data loss during brief power outages. Acoustic and optical signals enable quick identification of operating conditions. The compact design and low noise emission make the device suitable for use in offices and small server rooms. Certifications CE, RoHS, and REACH confirm compliance with European safety and environmental standards.