| Design |
| PDU types | Basic |
| Type | Single-phase |
| Rack capacity | 0U/1U |
| Mounting | Horizontal/Vertical |
| Product colour | Black |
| Features |
| Cable length | 2.5 m |
| Operational conditions |
| Operating temperature (T-T) | 0 - 45 °C |
| Storage temperature (T-T) | -25 - 65 °C |
| Operating relative humidity (H-H) | 0 - 95% |
| Storage relative humidity (H-H) | 0 - 95% |
| Ports & interfaces |
| AC outlets quantity | 12 AC outlet(s) |
| Power plug | C20 coupler |
| AC outlet types | C13 coupler, C19 coupler |
| I/O ports | Output Connections - (10)IEC 320 C13; (2)IEC 320 C19
Input Connection Type - IEC-320 C20 |
| Power |
| Load capacity | 3680 VA |
| Maximum input current per phase | 16 A |
| Maximum power | 3680 W |
| Weight & dimensions |
| Width | 447 mm |
| Depth | 57.2 mm |
| Height | 44.5 mm |
| Weight | 980 g |
The APC Rack PDU, model AP9559, is a
standard power distribution unit (PDU) for use in server racks. It enables efficient distribution of alternating current to multiple devices within a data center or IT infrastructure. The unit is designed as a
single-phase PDU and offers a
rack capacity of 0U/1U, allowing it to be mounted either horizontally or vertically. The
product color is black, enabling seamless integration into standard rack environments.
Applications
This PDU is designed for use in IT and server environments where reliable and uniform power supply to multiple devices is required. It is particularly suitable for racks with standard 19-inch format, serving as a central power distribution unit. The
operating temperature range of 0 to 45 °C and
storage temperature range of -25 to 65 °C make the device suitable for use in controlled indoor environments, with operating relative humidity up to 95%.
Functions and Features in Detail
The APC AP9559 features
12 AC outlets, distributed as
10 C13 connectors and
2 C19 connectors. These connector types are standard in IT and server technology and allow connection to a wide range of devices such as servers, switches, routers, or network equipment. The
input connector is a C20 connector, which connects to a suitable power source. The
cable length is 2.5 meters, allowing flexible positioning of the PDU within the rack.
Technology Explained Simply
The PDU provides a
maximum power output of 3680 watts and a
power capacity of 3680 VA, corresponding to a maximum current draw of
16 amperes per phase. These values are sufficient for powering multiple medium-sized IT devices. Power supply is via a
network cable with IEC-320 C20 plug, connected to an appropriate power source. The outlets are
always on, meaning that power supply to connected devices cannot be controlled via the PDU — it serves purely as a power distribution unit.
Compatibility and Accessories
The PDU is compatible with standard 19-inch rack installations. Installation is performed using
rack mounting brackets, which are required for mounting. The
C13 and C19 outlets are universally compatible and fit most IT and network devices. The PDU is a
basic model without additional control functions such as network monitoring or remote control.
Installation and Mounting
Mounting is done horizontally or vertically in the rack. The
dimensions are 447 mm (width) × 57.2 mm (depth) × 44.5 mm (height), enabling compact placement. The unit weighs
980 grams and is therefore easy to handle. The mounting brackets allow secure fastening in the rack. The cable length of 2.5 meters provides sufficient clearance for connecting to the power source.
Operational Advantages
The APC AP9559 offers
reliable power distribution with a clear focus on functionality and compatibility. The combination of C13 and C19 outlets enables power supply to various device types. The
low depth of 57.2 mm ensures the PDU can fit even in tight rack environments. The
maximum power output of 3680 W is sufficient for powering multiple servers or network devices. The
input voltage of 208/230 V is suitable for European and North American applications. The
operating temperature range of 0 to 45 °C covers most indoor conditions in server rooms.
The PDU is designed as a
standard model without additional control functions, making it especially suitable for users requiring simple, reliable power distribution without network control. The
cable length of 2.5 meters and
horizontal/vertical mounting options increase installation flexibility. The
outlets are always on, ensuring uncomplicated power supply, although remote control or load monitoring is not possible.