| Certificates |
| Certification | RoHS |
| Design |
| PDU types | Metered, Switched |
| Rack capacity | 0U |
| Mounting | Horizontal |
| Product colour | Black |
| Logistics data |
| Total carbon footprint (kg of CO2e) | 1306.78 |
| Management features |
| Monitoring | Current, Power, Voltage |
| Outlet control | Lock-out, Recycle, Turn off, Turn on |
| Ports & interfaces |
| AC outlets quantity | 8 AC outlet(s) |
| Power plug | IEC309 |
| AC outlet types | C13 coupler, C19 coupler |
| Power |
| Load capacity | 3680 VA |
| Maximum input current per phase | 16 A |
| Maximum total current draw per phase | 16 A |
| Maximum power | 3680 W |
| Weight & dimensions |
| Width | 56 mm |
| Depth | 46 mm |
| Height | 988 mm |
| Weight | 3.23 kg |
The APC Rack PDU 2G with switching function, type AP8958EU3, is a 0U
Rack-Power-Distribution-Unit (PDU) for use in IT infrastructures. It serves for central power distribution and control in server racks and enables precise monitoring and individual control of connected devices. The unit is horizontally mountable and black in colour, featuring a compact design with a height of 988 mm, width of 56 mm, and depth of 46 mm. It includes eight
AC outputs, divided into seven
C13 connectors and one
C19 connector, allowing flexible connection of various IT devices. Power supply is via an
IEC309 plug, ensuring a secure and standardised connection.
Applications
This PDU is designed for use in data centres, server rooms, and other IT environments where controlled power distribution and monitoring are required. It is particularly suitable for applications where avoiding power surges, overloads, or unauthorised access to power outlets is a priority. The ability to remotely control individual outputs is especially useful for restoring failed systems or performing scheduled reboots without requiring physical access to the rack.
Functions and Equipment in Detail
The PDU provides a
switching function, enabling each of the eight outputs to be individually turned on, off, locked, or recycled (restarted). These functions are accessible via network interfaces and support remote control.
Output control also includes the ability to lock outputs to prevent unauthorised access. Additionally, delay times for turning on and off can be defined to minimise power surges that may occur when multiple devices are powered on simultaneously.
Technology Explained Simply
The PDU continuously monitors
current,
power, and
voltage of connected loads. Maximum power is 3680 W, with a load capacity of 3680 VA, and maximum input current per phase is 16 A. These values ensure stable power supply for multiple IT systems. Real-time monitoring allows tracking of total power consumption in the rack and early detection of potential overloads. User-defined alarm thresholds trigger warnings when specific limits are exceeded, increasing proactivity in avoiding outages.
Compatibility and Accessories
The PDU is designed for use with standard IT devices equipped with C13 or C19 connectors. As an alternative or successor model, the RACK PDU 9000 SWITCHED ZEROU APDU9959EU3 is offered, providing similar functions. Control is performed via
web interfaces,
SNMP, or
Telnet, enabling integration into existing network management systems. Use of APC management platforms such as InfraStruxure Central, Capacity Manager, or Change Manager is also supported to centralise control and monitoring.
Mounting and Installation
Horizontal mounting is done directly in the rack, with the 0U form factor requiring no vertical space. Installation is straightforward, as the PDU connects to the power supply via an IEC309 plug. Devices are connected using the integrated C13 and C19 connectors. Configuration and control are performed via network interfaces, with no additional tools or software required.
Operational Advantages
Centralised control and monitoring of power supply increases efficiency and security of the IT infrastructure. The ability to remotely control individual outputs reduces physical access to the rack and minimises downtime. Real-time monitoring of power parameters enables proactive fault detection and resolution. Defined delay times when powering on prevent power surges and protect connected devices. Certification to
RoHS ensures environmentally compatible manufacturing.
Certification and Environment
The device complies with the
RoHS directive, which prohibits the use of certain hazardous substances in electrical equipment. The total carbon dioxide footprint is 1306.78 kg CO2e, reflecting the environmental impact of the product. The PDU is designed for indoor use and requires no additional protection against environmental influences.