| Design |
| PDU types | Metered, Switched |
| Type | Single-phase |
| Rack capacity | 0U |
| Mounting | Vertical |
| Product colour | Black |
| Features |
| Cable length | 3.05 m |
| Operational conditions |
| Operating temperature (T-T) | -25 - 65 °C |
| Storage temperature (T-T) | -5 - 45 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Packaging data |
| Package weight | 9.95 kg |
| Package width | 165 mm |
| Package depth | 124 mm |
| Package height | 2040 mm |
| Ports & interfaces |
| AC outlets quantity | 24 AC outlet(s) |
| Power plug | IEC309 |
| AC outlet types | C13 coupler, C19 coupler |
| Input connection type | IEC 309 32A 2P+E |
| Output connections | (21) IEC 320 C13, (3) IEC 320 C19 |
| Power |
| AC input frequency | 50 - 60 Hz |
| Maximum input current per phase | 32 A |
| Maximum total current draw per phase | 32 A |
| Weight & dimensions |
| Width | 56 mm |
| Depth | 46 mm |
| Height | 1829 mm |
| Weight | 7.59 kg |
The APC AP8953 is a
Switched Rack Power Distribution Unit (PDU) designed for central power distribution in IT racks. It enables individual control and monitoring of 24 AC outlets, with power supply via an IEC 309 32A 2P+E plug. The PDU is designed as a
0U module, meaning it does not occupy any rack units and is mounted vertically. Its design is optimized for use in server and network racks, with the
black color and compact form factor (56 mm width, 46 mm depth, 1829 mm height) allowing integrated mounting in existing rack systems.
Applications
The AP8953 is intended for environments where precise control of power supply for IT systems is required. It is typically used in data centers, server rooms, or other IT infrastructures where avoiding power surges, overloads, and unauthorized access to power outlets is critical. The PDU also helps reduce downtime by enabling remote control of outlets to restore failed systems without physical access.
Functions and Equipment in Detail
The PDU features
24 AC outlets, distributed as (21) IEC 320 C13 and (3) IEC 320 C19 connectors. These connector types are standard in IT systems and allow powering of servers, switches, routers, and other network devices. The
Switched function allows each outlet to be turned on, off, or locked individually to prevent unauthorized access. Additionally,
delay times for turning outlets on and off can be defined to avoid power surges during system startup. This is particularly important when multiple devices are powered on simultaneously, potentially causing high inrush currents.
Technology Explained Simply
Power supply is provided via a
3.05 m long cable with an IEC 309 32A 2P+E plug, connected to a 230 V mains supply. The maximum current draw is
32 A per phase, corresponding to a total power of up to 7.36 kW (at 230 V). The PDU is designed for an operating frequency of 50 to 60 Hz, enabling use in Europe and other regions with matching frequency. Power monitoring occurs in real time, with total consumption displayed locally on a digital screen. This allows quick identification of overloads before damage or failure occurs.
Compatibility and Accessories
The AP8953 is designed for use with standard IT devices equipped with C13 or C19 connectors. Network management functions allow configuration and monitoring via
web interface, SNMP, or Telnet, enabling integration into existing network management systems. Compatibility with APC platforms such as InfraStruxure Central, Capacity Manager, or Change Manager is also possible, allowing centralized control of multiple PDUs.
Mounting and Installation
The PDU is mounted vertically and designed for tool-free installation in rack systems. Mounting is done on the rear wall of the rack, with vertical orientation ensuring optimal space utilization. The cable length of 3.05 m provides sufficient slack for connection to the power source without requiring additional extensions.
Operational Advantages
Remote control of outlets allows flexible management of IT system power supply. This enables rebooting devices without physical access, reducing maintenance time. Setting delay times ensures a controlled startup sequence, enhancing system stability. Monitoring power consumption and setting alarm thresholds help detect and prevent overloads early. Network integration enables centralized management and monitoring, increasing the efficiency of IT infrastructure.
Operating Conditions
The PDU can operate at temperatures from -25 to 65 °C and relative humidity from 5 to 95 %. Storage conditions are from -5 to 45 °C and relative humidity from 5 to 95 %. These specifications make the AP8953 suitable for use in various environments, including rooms with variable temperature and humidity.