Further information for APC AP8886 Rack PDU 0HE with metering
Certificates
Compliance certificates
RoHS
Certification
EN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE
REACH: No SVHCs
Design
PDU types
Metered
Rack capacity
0U
Mounting
Vertical
Product colour
Black
Features
Cable length
1.83 m
LED indicators
Logistics data
Total carbon footprint (kg of CO2e)
57837.86
Management features
Monitoring
Current, Power, Voltage
Operational conditions
Operating temperature (T-T)
0 - 55 °C
Storage temperature (T-T)
-25 - 65 °C
Operating relative humidity (H-H)
5 - 95%
Storage relative humidity (H-H)
5 - 95%
Operating altitude
0 - 3000 m
Non-operating altitude
0 - 15000 m
Packaging data
Package weight
11.6 kg
Package width
170 mm
Package depth
112 mm
Package height
2050 mm
Ports & interfaces
AC outlets quantity
42 AC outlet(s)
Power plug
IEC309
AC outlet types
C13 coupler, C19 coupler
Output connections
30 x IEC 320 C13
12 x IEC 320 C19
Power
Nominal input voltage
400 V
AC input frequency
50 - 60 Hz
Maximum current
32 A
Nominal output voltage
230 V
Load capacity
22080 VA
Maximum input current per phase
32 A
Power protection features
Overload
Maximum power
22000 W
Weight & dimensions
Width
56 mm
Depth
51 mm
Height
1829 mm
Weight
8.72 kg
The APC Rack Power Distribution Unit AP8886 is a measurement device for use in data centres and IT infrastructures. It is a 0U rack PDU with vertical mounting, designed for the distribution and monitoring of electrical power in server racks. The unit is finished in black and features a cable length of 1.83 m, equipped with an IEC 309 plug, to connect to a three-phase mains voltage of 400 V. The outputs deliver a nominal voltage of 230 V and are rated for a maximum power of 22,000 W (22,080 VA), with a maximum input current per phase of 32 A.
Applications
The AP8886 is intended for use in professional IT environments such as data centres, server rooms, or data hubs, where precise power distribution and monitoring are required. The measurement function enables active monitoring of current, power, and voltage, allowing data centre managers to optimise load distribution and avoid overloads. The energy monitoring supports decision-making for IT system sizing and contributes to reducing overall operating costs.
Functions and Features in Detail
The unit features 42 AC outlets, divided into 30 x IEC 320 C13 and 12 x IEC 320 C19, suitable for connecting servers, network devices, and other IT systems. The outlets are equipped with locking mechanisms to ensure a secure and stable connection. LED indicators provide visual status information directly on the unit. An integrated overload protection safeguards the circuits from damage due to excessive load.
Technology Explained Simply
The measurement function continuously monitors current, active power, and voltage. These data can be retrieved via a secure web connection, SNMP-, or Telnet interface. Users can set individual alarm thresholds, triggering real-time warnings for impending overloads directly on the unit and on remote systems. The energy consumption data support planning and optimisation of IT infrastructure. The IEC 309 plug connection ensures a robust and standardised connection to the power supply.
Compatibility and Accessories
The AP8886 is designed for use in rack systems and can be combined with various APC platforms for central management, including InfraStruxure Central, Operations, Capacity, and Energy Efficiency. These systems enable central control and monitoring of multiple PDUs. The IEC outlets are compatible with common IT equipment. An input for temperature and humidity sensors is also available to monitor environmental conditions within the rack.
Mounting and Installation
Mounting is performed vertically in the rack, where the unit requires 0U rack capacity, meaning it does not occupy vertical space within the rack. Installation is carried out via the IEC 309 cable, which connects to a three-phase power supply. The outlets are arranged for easy access and efficient cabling.
Operational Advantages
The real-time monitoring of power parameters enables proactive operations management and minimises the risk of power outages. The individually adjustable alarm thresholds help detect potential issues early. The energy consumption data support load distribution planning and IT system sizing. The robust construction and certification to EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE, as well as RoHS compliance, ensure safe and reliable operation. The operating temperature ranges from 0 to 55 °C, with operating relative humidity of 5 to 95 %, making the unit suitable for demanding environments. The maximum operating altitude is 3000 m above sea level.