APC AP8681, EAN: 0731304299530

APC AP8681 Rack PDU 2G Metered by Outlet switching function ZeroU

UPS > Accessories

APC AP8681 Rack PDU 2G Metered by Outlet switching function ZeroU

Lieske Part No. 2013951
Mfg Part No AP8681
EAN-Code 0731304299530
Manufacturer APC
Here only 4.629,35 EUR
5.508,93 EUR incl. VAT

Further information for APC AP8681 Rack PDU 2G Metered by Outlet switching function ZeroU

Certificates
Compliance certificatesRoHS
CertificationEN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, UL, VDE
Design
PDU typesMetered, Metered-by-outlet, Switched
Rack capacity0U
MountingVertical
Product colourBlack
Features
Cable length1.83 m
Logistics data
Total carbon footprint (kg of CO2e)10364.02
Management features
MonitoringCurrent, Power, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Operating relative humidity (H-H)5 - 95%
Storage relative humidity (H-H)5 - 95%
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m
Packaging data
Package weight10.5 kg
Package width162 mm
Package depth117 mm
Package height2038 mm
Ports & interfaces
AC outlets quantity24 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power
Nominal input voltage400 V
AC input frequency50 - 60 Hz
Maximum current16 A
Nominal output voltage230 V
Load capacity11040 VA
Maximum input current per phase16 A
Maximum total current draw per phase16 A
Maximum power11040 W
Weight & dimensions
Width56 mm
Depth51 mm
Height1829 mm
Weight8.23 kg
APC Metered by Outlet power distribution units optimize energy use and protect circuits by collecting measurements at each outlet. Current measurements enable real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide energy consumption data, enabling data center managers to make informed decisions about load balancing and proper sizing of IT environments and reducing total cost of ownership. The devices have numerous functions and features: active power monitoring, temperature/humidity sensor connection, IEC sockets with locking and ultra-slim circuit breakers. Metered by Outlet Rack PDUs are configured via a secure web connection or SNMP or Telnet interface. APC platforms for central management such as InfraStruxure Central, Operations, Capacity and Energy Efficiency are available as complementary management solutions.