APC AP4421A, EAN: 0731304432425

APC AP4421A Rack ATS 1HE 10A C14 IN 12 C13 OUT

19 Inch-Technology > Accessories/Equipment > Energy Management

APC AP4421A Rack ATS 1HE 10A C14 IN 12 C13 OUT

Lieske Part No. 1124576
Mfg Part No AP4421A
EAN-Code 0731304432425
Manufacturer APC
Here only 1.894,30 EUR
2.254,22 EUR incl. VAT

Further information for APC AP4421A Rack ATS 1HE 10A C14 IN 12 C13 OUT

Design
Form factorRackmount
Rack capacity1U
Product colourBlack
DisplayLCD
Operational conditions
Operating temperature (T-T)-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95%
Ports & interfaces
AC outlets quantity12 AC outlet(s)
AC outlet typesC13 coupler
Power
Input operation voltage (min)207 V
Input operation voltage (max)253 V
AC input frequency50 - 60 Hz
Input current10 A
Output current10 A
Technical details
Total carbon footprint (kg of CO2e)450.72
Weight & dimensions
Width432 mm
Depth236 mm
Height44 mm
Weight3.93 kg
The APC NetShelter Rack Automatic Transfer Switch (ATS) AP4421A is a 1U rack device for secure and redundant power supply of IT equipment in data centres or edge infrastructures. As a single-phase ATS with a rated current of 10A and a rated voltage of 230V, it offers a load capacity of 2000VA and is specifically designed for single-cable devices operated via a single power connection. The device features two inputs with IEC C14 sockets and twelve outputs with IEC C13 connectors, enabling multiple devices to be connected to two independent power sources and automatically switching to the alternative power supply in case of failure. The switching occurs without interruption of power supply to ensure high availability of connected devices.

Applications

The AP4421A is designed for use in IT racks where redundant power supply is required to minimise downtime. It is particularly suitable for environments where power supply is critical, such as data centres, server rooms, or network and security devices. The installation width of 432 mm, depth of 236 mm, and height of 44 mm (1U) allow for compact mounting in standard 19-inch racks. The device is designed for operation in a temperature range of -5 °C to 45 °C and can be operated at a relative humidity of 5 % to 95 % (non-condensing).

Features and Equipment in Detail

The device is equipped with an integrated Network Management Card 3 (NMC3), enabling comprehensive monitoring and control via various protocols. Users can access the device, make settings, and monitor its operating status via a secure web user interface, SNMP (Simple Network Management Protocol), and CLI (Command Line Interface). The NMC3 also supports sharing of network connections and enables integration into EcoStruxure IT systems, improving manageability and scalability in larger IT infrastructures. The integrated environmental monitoring allows for the collection of operational parameters such as temperature and power consumption.

Technology Explained Simply

The ATS continuously monitors both input lines and automatically switches to the active power source if one of the lines experiences a voltage failure or voltage outside the permissible range of 207 V to 253 V. The input frequency ranges between 50 Hz and 60 Hz, ensuring compatibility with various power grids worldwide. The maximum input current is 10 A, and the output current is also limited to 10 A to ensure safe load distribution. Power supply is provided via two separate C14 inputs, which can be connected to different power sources (e.g., two different power supplies or a mains and an UPS).

Compatibility and Accessories

The AP4421A is fully compatible with EcoStruxure IT, enabling integration into existing management and monitoring systems. The use of IEC C13 outputs ensures compatibility with a wide range of IT devices that use standard power sockets. The integrated NMC3 supports various network protocols and enables remote maintenance and configuration via LAN, WLAN, or serial interfaces. Device management is performed via a web UI, SNMP, and CLI, allowing administrators flexible access to the device.

Mounting and Installation

The device is designed as a rackmount module and can be mounted in standard 19-inch racks. Mounting is done using integrated rack mounting brackets to ensure secure fastening. Installation requires connecting the two input lines to separate power sources and connecting the outputs to the IT devices to be protected. Configuration is performed via the integrated NMC3, with network settings (IPv4, IPv6) configurable via a web interface or CLI. Firmware can be updated via FTP, SCP, or USB storage device.

Operational Advantages

The AP4421A provides high availability through automatic switching during power failure, ensuring uptime for critical IT systems. The integrated network monitoring enables proactive fault detection and resolution. Compatibility with EcoStruxure IT and support for various management protocols simplify integration into existing IT infrastructures. The standard 2-year warranty and the option for a 5-year extended warranty provide additional operational security. The device is designed for indoor use and complies with standards EN 55022 Class A and FCC Part 15 Class A. The maximum operating altitude is 3048 metres, enabling use at high elevations. The device is RoHS-compliant and meets the requirements of the China RoHS regulation.

Product Type, Core Function, Technology, Standard

The device is a Rack ATS (Automatic Transfer Switch), whose core function is automatic switching between two power sources in case of failure of one source. The technology is based on an integrated Network Management Card 3 (NMC3) with support for web UI, SNMP, and CLI. The standard EN 55022 Class A and FCC Part 15 Class A ensures electromagnetic compatibility. The product colour is black, and the device is designed in a 1U rack format. The operating temperature ranges from -5 °C to 45 °C, and the relative humidity during operation is 5 % to 95 %.

The device is designed for use in IT racks where redundant power supply is required to minimise downtime. It is particularly suitable for environments where power supply is critical, such as data centres, server rooms, or network and security devices. The installation width of 432 mm, depth of 236 mm, and height of 44 mm (1U) allow for compact mounting in standard 19-inch racks. The device is designed for operation in a temperature range of -5 °C to 45 °C and can be operated at a relative humidity of 5 % to 95 % (non-condensing).