Further information for AEG 30919557 SNMP Pro Slot and Sensors
Features
Product type
Network management card
Packaging content
Manual
Ports & interfaces
Ethernet LAN (RJ-45) ports
1
Ethernet interface type
Fast Ethernet
Ethernet LAN data rates
10,100 Mbit/s
Weight & dimensions
Width
60 mm
Depth
44 mm
Height
120 mm
Weight
66 g
The AEG Network Management Card, type 30919557, is a communication extension for Uninterruptible Power Supply (UPS) systems of the Protect series from AEG Power Solutions. It enables integration of the UPS into existing network management systems and provides functions for remote monitoring, automated control, and event processing. The card is designed as an internal slot card and is directly integrated into the UPS, making the device's operational status available over the network.
Applications
The card is designed for use in IT infrastructures where continuous power supply availability and central monitoring of UPS systems are required. It is particularly suitable for data centers, server rooms, and critical IT systems where an orderly system shutdown is necessary in the event of a power failure. Integration with network management software such as HP OpenView or SunNetManager enables centralized control and monitoring of multiple UPS devices from a single point.
Functions and Equipment in Detail
The card features an Ethernet connection (RJ-45) with Fast Ethernet technology (10/100 Mbit/s), enabling communication over the local network. Via this connection, the UPS status can be accessed through a web browser, allowing visual representation of operational parameters such as charge level, load, and operating mode. The card supports transmission of notifications via email, SMS, or network messages, enabling prompt alerts in case of faults or critical events.
Technology Explained Simply
The card integrates an SNMP agent according to RFC1628, enabling communication with network management software. This agent collects data on the UPS operational status and makes it available to external systems. The Wake-on-LAN function allows servers to be automatically restarted after a power failure, while the staged shutdown capability for servers during a power failure ensures data integrity. The card is powered internally by the UPS, eliminating the need for additional power supply.
Compatibility and Accessories
The card is intended for UPS series Protect B. (from B.1500), C., 1., and 1.M. It is part of the PRO variant of the SNMP adapter, which offers additional functions such as integration with access control systems, air conditioning units, or smoke and fire alarm systems. In combination with the EnvironmentManager, the card can also process data from temperature and humidity sensors, enabling monitoring of environmental conditions in the server room.
Installation and Mounting
The card is installed as an internal slot card into the UPS. Installation is performed by inserting it into the designated slot within the UPS. Network connection is established via the RJ-45 network cable. Configuration is done through the integrated web interface or via network management software. The operating manual is included in the delivery and supports setup.
Operational Advantages
The card enables centralized, automated monitoring and control of the UPS, reducing response time in case of faults. The staged shutdown capability for servers protects against data loss, while the automatic restart function accelerates operational recovery. Integration into existing network management systems reduces administrative effort and enables efficient operations management.