Further information for ABB Automation GJL1213909R0011 motor protection switch VBC6-30-01-P-01
General
Function
Reversing safety
Rated control supply voltage Us at DC
24
Voltage type for actuating
DC
Rated operation current Ie at AC-3, 400 V
9
Rated operation power at AC-3, 400 V
4
Rated operation power NEMA
1.4914
Type of electrical connection of main circuit
PCB connection
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Depth
47.7
Height
57.5
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
0
Number of main contacts as normally open contact
3
Number of normally closed contacts as main contact
0
Operating voltage at AC 50 Hz
690
Operating voltage at AC 60 Hz
690
Operating voltage at DC
2.5
Rated operation current Ie at AC-1, 400 V
6
Type of electrical connection for auxiliary- and control current circuit
Other
Voltage type (operating voltage)
DC
Width
96.2
Rail mounting possible
The ABB compact reversing contactor VBC6-30-01-P-01 is a compact switching drive for controlling motors with clockwise and counterclockwise rotation in industrial applications. It belongs to the VB/VBC 6 series and is designed for a rated operational power of 4 kW at AC-3 and 400 V. Control is performed via a DC voltage of 24 V, with the operating voltage for the main circuit reaching up to 690 V AC (50 Hz and 60 Hz) as well as 2.5 V DC. The device is designed as a reversing contactor with mechanical interlock to ensure safe switching between operating states. The main circuit connection is via printed circuit board connection, enabling flexible integration into existing control systems. The protection rating IP20 and NEMA 1 indicate suitability for indoor use where no special protection requirements against dust or moisture exist.
Applications
This contactor is intended for use in industrial control systems, particularly in installations controlling motors with low to medium power, such as conveyor systems, pumps, or small machines. Its compact design with a width of 96.2 mm, height of 57.5 mm, and depth of 47.7 mm makes it especially suitable for installations with limited space. The mechanical interlock ensures that both switching positions cannot be activated simultaneously, ensuring safe operation. The VB/VBC 6 series is specifically designed for applications requiring high packing density in enclosures.
Functions and Equipment in Detail
The device features three main contacts as make contacts, responsible for conducting the main current in the power circuit. It includes one auxiliary contact as a break contact, which can be used for additional control or signaling functions. Control is performed via a DC voltage of 24 V, with the rated control supply voltage also being 24 V DC. The electrical connection type for auxiliary and control circuits is specified as other, indicating a specific, non-standard connection method. Rail mounting is possible, enabling easy installation in standard control panels.
Technology Explained Simply
The reversing contactor switches the motor circuit between two positions—for example, for changing rotation direction. The mechanical interlock prevents both contacts from closing simultaneously, eliminating the risk of a short circuit. Control via DC voltage is common in many industrial control systems. The rated operational power of 4 kW at AC-3 and 400 V corresponds to a typical load for small to medium motors. The main circuit operating voltage of up to 690 V AC makes the device suitable for higher voltages, while the control voltage remains constant at 24 V DC. The IP20 protection rating protects against finger contact and larger solid objects, but is not intended for damp or dusty environments.
Compatibility and Accessories
Compatible accessories include thermal and electronic overload relays such as models T16-4.2, T16-3.1, E16DU-2.7, or E16DU-6.3, which can be used for motor protection functions. Additionally, varistor snubber units such as RV-BC6/60 or RV-BC6/250 are available to suppress voltage surges. A reversing connector such as BSM6-30 enables flexible wiring. These components can be mounted front-side, allowing modular expansion of the device’s functionality.
Mounting and Installation
Mounting is done via rail, enabling quick and secure installation in standard control panels. The main circuit connection type is a printed circuit board connection, allowing direct connection to cables or circuit boards. Control is performed via a DC voltage of 24 V, with the control voltage connection points to be connected according to technical specifications. The mechanical interlock must be considered during installation to ensure correct switching operation.
Operational Advantages
The reversing contactor offers a compact design that saves space in enclosures. The mechanical interlock increases operational safety by preventing simultaneous switching of both positions. The use of 24 V DC for control is common in many industrial control systems and allows for easy integration. The ability to mount additional accessories such as overload relays or snubber units expands the device’s functionality without requiring additional space. Rail mounting simplifies installation and maintenance.