Further information for ABB Automation 2TLA020054R0000 Tina 1A Plug
General
Type of connector for trunk line
M12
Number of sensor-/actuator-slots
1
Number of channels per connector slot
1
Type of branches for sensor-/actuator cables
M12
Number of poles sensor/actuator slots
5
Rated voltage
24
Pollution degree
2
Operating voltage
24
Max. current carrying capacity per I/O signal
2
Max. current carrying capacity per socket
2
Max. total current
2
Material contact body
Copper
Material of contact surface
Gold
Material insulation body
PBT
Thread sleeves sensor/actuator slots
M12
Material housing
Plastic
Colour housing
Black
Operation temperature
55
Degree of protection (IP)
IP67
Explosion safety category for gas
None
Explosion safety category for dust
None
Width
48
Height
23
Length
15
With LED indication
With potential separation
Connection for NPN-sensors
Fix cable version suitable for cable guide chain
The Tina devices adapt safety sensors with mechanical contacts such as emergency stop buttons,
switches and light grids/curtains with two outputs to the DYNlink safety circuit in Vital
and Pluto. This means that PLe according to EN ISO 13849-1 and SIL 3 according to EN 62061 and EN 61508 is met
with the connected safety sensors and the Vital/Pluto controller