| General |
| Model | Other |
| Type of electric connection | Screw connection |
| Evaluation inputs | 1-channel |
| Release-delay | 48 |
| Number of outputs, safety related, undelayed, with contact | 2 |
| Number of outputs, safety related, delayed, with contact | 0 |
| Number of outputs, safety related, undelayed, semiconductors | 0 |
| Number of outputs, safety related, delayed, semiconductors | 0 |
| Number of outputs, signalling function, undelayed, with contact | 0 |
| Number of outputs, signalling function, delayed, with contact | 0 |
| Number of outputs, signalling function, undelayed, semiconductors | 0 |
| Number of outputs, signalling function, delayed, semiconductors | 0 |
| Type of safety acc. IEC 61496-1 | 4 |
| Stop category acc. IEC 60204 | 0 |
| Performance level acc. EN ISO 13849-1 | Level e |
| SIL according to IEC 61508 | 3 |
| Width | 22.5 |
| Height | 84 |
| Depth | 120 |
| Control voltage 1 | 24 |
| Control voltage 2 | 24 |
| Operating voltage at DC | 24 |
| Power consumption | 3 |
| Supply voltage DC | 24 |
| Type of control voltage 1 | DC |
| Type of control voltage 2 | DC |
| Voltage type (operating voltage) | DC |
| Voltage type of supply voltage | DC |
| Suitable for monitoring of position switches | |
| Suitable for monitoring of emergency-stop circuits | |
| Suitable for monitoring of valves | |
| Suitable for monitoring of optoelectronic protection equipment | |
| Suitable for monitoring of tactile sensors | |
| Suitable for monitoring of magnetic switches | |
| Suitable for monitoring of proximity switches | |
| Rail mounting possible | |
| With detachable clamps | |
| With start input | |
| With muting function | |
| With feedback circuit | |
| With approval for BG BIA | |
| With approval according to UL | |
can monitor up to 30 sensors, such as Eden, according to the highest security level