Further information for ABB Automation 2TLA010053R0400 Sentry SSR42 safety relay 24 V DC
General
Model
Other
Type of electric connection
Screw connection
Evaluation inputs
One- and two-channel
Release-delay
20
Number of outputs, safety related, undelayed, with contact
2
Number of outputs, safety related, delayed, with contact
2
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, safety related, delayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
0
Number of outputs, signalling function, delayed, with contact
0
Number of outputs, signalling function, undelayed, semiconductors
0
Number of outputs, signalling function, delayed, semiconductors
0
Type of safety acc. IEC 61496-1
4
Stop category acc. IEC 60204
0 + 1
Performance level acc. EN ISO 13849-1
Level e
SIL according to IEC 61508
3
Width
22.5
Height
120
Depth
120
Control voltage 1
24
Control voltage 2
24
Operating voltage at DC
24
Power consumption
6
Rated switch current
3
Supply voltage DC
24
Type of control voltage 1
DC
Type of control voltage 2
DC
Voltage type (operating voltage)
DC
Voltage type of supply voltage
DC
Suitable for monitoring of position switches
Suitable for monitoring of emergency-stop circuits
Suitable for monitoring of valves
Suitable for monitoring of optoelectronic protection equipment
Suitable for monitoring of tactile sensors
Suitable for monitoring of magnetic switches
Suitable for monitoring of proximity switches
Rail mounting possible
With detachable clamps
With start input
With muting function
With feedback circuit
With approval for BG BIA
With approval according to UL
The ABB safety relay Sentry SSR42 is an industrial-grade relay for monitoring and safeguarding machine and plant functions. It serves as a central component in safety circuits and enables the monitoring of various input signals to ensure a safe shutdown in case of failure. The device is designed for use in systems with a supply voltage of 24 V DC and has a power consumption of 6 W. The operating voltage is also 24 V DC, with control voltages for both inputs also at 24 V DC. The unit is equipped with screw terminals, ensuring a secure and reliable connection. Mounting is done via support rails, enabling quick and standardized installation in enclosures. The removable terminals facilitate maintenance and replacement of the device.
Applications
The safety relay Sentry SSR42 is suitable for monitoring various safety components, including position switches, emergency stop circuits, valves, optoelectronic protective devices, magnetic switches, and proximity switches. It is not intended for monitoring tactile sensors. The application is particularly suited for systems requiring safe shutdown in case of faults or hazardous situations. The single-function models of the SSR series are suitable, for example, for monitoring contacts and OSSD signals as well as two-hand control operations. The feedback function enables safe confirmation of output signals, which is important for validating safety functions.
Functions and Features in Detail
The relay features two safety-oriented, non-delayed, contact-based outputs and two safety-oriented, delayed, contact-based outputs. The reset delay is 20 ms, enabling controlled shutdown when input signals fail. Input evaluation is performed in single- and dual-channel modes, allowing monitoring of redundant signals. An integrated start input initiates the relay’s operation. The Multi-Reset function allows resetting up to 10 Sentry safety relays with a single reset button, simplifying restart after a fault. The reset can be selected manually or automatically via a switch on the front of the device.
Technology Explained Simply
The safety functions of the relay are based on monitoring input signals and subsequently generating safe output signals. The outputs are contact-based, meaning they use mechanical contacts that offer high reliability and mechanical robustness. The delayed outputs ensure that shutdown does not occur immediately, but after a defined delay, to avoid false alarms. The feedback function ensures that output signals are correctly transmitted and that safety functions are actually activated. The device is powered by 24 V DC, which is a standard in industry and provides high stability. The rated switching current is 3 A, sufficient for most industrial applications.
Compatibility and Accessories
The relay is designed for use in safety systems complying with the requirements of standards IEC 61496-1, IEC 60204, and EN ISO 13849-1. It achieves Safety Type 4 according to IEC 61496-1, Stop Category 0 + 1 according to IEC 60204, and Performance Level e according to EN ISO 13849-1. The SIL class is 3 according to IEC 61508. UL certification is available, allowing the device to be used in regions with UL requirements. It does not have BG BIA certification. The Sentry series includes various models, including base models (BSR), single-function models (SSR), safety timers (TSR), and universal models (USR), which can be combined according to requirements. The Multi-Reset function enables linking multiple relays for centralized reset.
Mounting and Installation
Mounting is done via support rails, enabling standardized and quick installation in enclosures. Dimensions are 22.5 mm (width), 120 mm (height), and 120 mm (depth), allowing the device to fit in standard control panels. Screw terminals ensure a secure and durable connection. Removable terminals facilitate replacement and maintenance. The front of the device features a switch to select between manual and automatic reset, providing flexible operation.
Operational Advantages
The Sentry SSR42 safety relay offers high reliability through contact-based outputs and redundant input evaluation. The Multi-Reset function reduces maintenance effort, as multiple relays can be reset with a single button. The clear structure of the series allows flexible adaptation to different requirements. Compliance with international safety standards ensures usability in various industries and regions. The use of 24 V DC as supply voltage is widely adopted in industry and enables easy integration into existing systems.