ABB 2CTB803873R5600, EAN: 3660308520548

ABB 2CTB803873R5600 Surge Arrester T2 4p 20kA

Energy > Surge Protection

ABB 2CTB803873R5600 Surge Arrester T2 4p 20kA

Lieske Part No. 466635
Mfg Part No 2CTB803873R5600
EAN-Code 3660308520548
Manufacturer ABB
Here only 333,45 EUR
396,81 EUR incl. VAT

Further information for ABB 2CTB803873R5600 Surge Arrester T2 4p 20kA

General
Number of conductors (without earthing)4
Nominal discharge surge current (8/20)20
Nominal voltage AC230
Short-circuit breaking capacity (Isccr)100
Max. continuous voltage AC275
Max. discharge surge current (8/20)20
Mounting methodOther
Construction size4 modular spacing
Voltage protection level1.25
Max. conductor cross section solid (solid, stranded)25
Max. conductor cross section flexible (fine-strand)16
Signalling at the deviceOptic
Degree of protection (IP)IP20
System configuration DCno
System configuration ITno
System configuration TNyes
System configuration TN-Cno
System configuration TN-C-Syes
System configuration TN-Syes
System configuration TTno
System configuration otherno
With remote signalling contactno
Integrated backup fuseno
Category type 2yes
The ABB surge protection device OVR T2 4L 40-275 P QS is a protective device of Type 2 category, specifically designed for use in electrical installations to intercept indirect lightning effects and switching overvoltages. The device is installed near the supply point of the installation to protect sensitive consumers and electrical components from voltage surges. It features thermal monitoring QuickSafe®, ensuring safe and reliable operation of the device. The unit consists of a base part and a replaceable protection module, ensuring easy maintenance and replaceability.

Applications
The OVR T2 4L 40-275 P QS is intended for use in sub-distribution boards and final circuits. It is particularly suitable for installations operating in TN-S or TN-C-S network configurations, with a maximum continuous voltage up to 275 V AC. The nominal voltage is 230 V AC, making it suitable for typical low-voltage installations in buildings and industrial facilities. The protective device is not intended for network configurations such as TT, TN-C, or IT.

Functions and Equipment in Detail
The device is equipped with a mechanical function indicator, which optically signals the operating status. This indicator allows for quick visual inspection to confirm whether the protection is active. The QuickSafe® technology monitors the thermal load on the protection module and ensures that in the event of overload or failure, the protection module is safely disconnected to prevent secondary damage.

Technology Explained Simply
The OVR T2 4L 40-275 P QS provides a rated discharge current of 20 kA (8/20 µs), meaning it is capable of safely diverting short, high current surges, such as those occurring during overvoltages. The protection level is 1.25 kV, indicating the maximum voltage that can be applied to the device without causing a breakdown. The short-circuit withstand capability (Isccr) is 100 kA, indicating the maximum current the device can safely withstand during a short-circuit in the network. The module size is 4 TE, enabling installation in standard switchboards. The protection rating IP20 protects against finger contact and solid foreign objects, but is not suitable for outdoor use.

Compatibility and Accessories
The protective device is compatible with the System pro M compact series and can be mounted on phase rails for modular installation. This allows for flexible and modular integration into existing switchgear. The unit is designed for use with 4 conductors (without earth), with a maximum conductor cross-section of 25 mm² for rigid conductors and 16 mm² for flexible, fine-stranded conductors.

Mounting and Installation
Installation is carried out in switchboards or distribution boards, with the unit being installed as close as possible to the supply point of the electrical installation to ensure optimal protection. The module size of 4 TE allows for easy installation in standard switchboards. Connections are made via the designated terminal clamps, designed for the specified conductor cross-sections.

The Test Class Type 2 is complied with, meaning the device is suitable for use in the second protection level according to VDE 0160 and IEC 61643-11. This protection type is typically found near consumers or in sub-distribution boards, where voltage surges have already been reduced but are still high enough to cause damage.

Operational Advantages
The use of the OVR T2 4L 40-275 P QS provides reliable protection for electrical installations. The QuickSafe® technology enhances safety by detecting thermal overload and safely disconnecting the protection module. The mechanical function indicator allows for quick visual verification that the protection is active. Compatibility with the System pro M compact series simplifies integration into existing installations. Compliance with Test Class Type 2 and short-circuit withstand capability of 100 kA ensures high reliability and safety during operation.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/466635
qrcode für ABB 2CTB803873R5600 Surge Arrester T2 4p 20kA