ABB 2CSF204123R1400, EAN: 8012542820208

ABB 2CSF204123R1400 RCD 4P Type A 40A 30mA

Installation > Modular devices / equipment installation > RCD

ABB 2CSF204123R1400 RCD 4P Type A 40A 30mA

Lieske Part No. 126243
Mfg Part No 2CSF204123R1400
EAN-Code 8012542820208
Manufacturer ABB
Here only 136,80 EUR
162,79 EUR incl. VAT

Further information for ABB 2CSF204123R1400 RCD 4P Type A 40A 30mA

General
Number of poles4
Rated current40
Rated impulse withstand voltage Uimp4
Mounting methodDIN rail
Leakage current typeA
Frequency50/60 Hz
Degree of protection (IP)IP20
Width in number of modular spacings4
Built-in depth69
Ambient temperature during operating55
Pollution degree2
Connectable conductor cross section multi-wired25
Connectable conductor cross section solid-core25
Depth of device69
Height of device85
RAL-number (akin)7035
Width of device70
Selective protectionno
Short-time delayed trippingno
Additional equipment possibleyes
With interlocking deviceyes
Explosion-proofno
The residual current circuit breaker F204 A-40/0.03-L from ABB is a 4-pole circuit breaker for use in electrical installations in accordance with standards DIN VDE 0100-410 and DIN VDE 0100-530. It provides protection for persons, property, and fire protection by disconnecting in the event of detecting a fault current. The F200 series offers protection against sinusoidal alternating currents and pulsating currents with a smooth direct fault current component up to 6 mA, which is particularly relevant for modern electronic devices. The switch is designed for use in household, commercial, and industrial applications and complies with product standards IEC/EN 61008-1, 61008-2-1, 61543 (corresponding to VDE 0664-10, -11, -30) as well as UL 1053 for Type A up to 100 A.

Applications
This circuit breaker is intended for use in electrical distributions where protection against indirect contact, additional protection (IΔn = 30 mA), and fire protection (IΔn = 300 mA) is required. It is particularly suitable for installations where electronic devices with direct current components in the fault current are present, such as in photovoltaic systems, LED lighting systems, or devices with switch-mode power supplies. Mounting is done on DIN rail, enabling flexible integration into distribution boxes.

Functions and Equipment in Detail
The switch has a rated current of 40 A and a residual current trip value of 30 mA (IΔn = 0.03 A), meeting the standard for additional protection. It is designed as Type A, meaning it can detect both alternating and pulsating direct fault currents. The number of poles is 4, with the neutral conductor (N) connected on the left — this is relevant for installations with a 3-phase network without a neutral conductor or when the neutral conductor must be positioned on the left. The protection class IP20 ensures protection against contact with solid objects and against vertically falling water droplets, but not against splashing water or dust. The operating ambient temperature is up to 55 °C, which is sufficient for indoor installations under typical operating conditions.

Technology Explained Simply
The switch operates on the principle of a residual current circuit breaker (RCCB), where the sum of the currents in all conductors (L1, L2, L3, N) is monitored. If this sum deviates from zero — i.e., a fault current occurs — the switch trips within milliseconds. The rated impulse voltage withstand of 4 kV ensures functionality during transient voltage surges. The mounting depth is 69 mm, and the device dimensions are 70 mm (width) × 85 mm (height) × 69 mm (depth), corresponding to the standard width of 4 module units. The connection cross-sections for single-core and multi-core conductors are up to 25 mm² each, enabling connection to common installation cables. Pollution degree class 2 is suitable for environments with low pollution, such as indoor spaces without dusty or humid conditions.

Compatibility and Accessories
Additional functionality can be extended with optional accessories. Suitable accessories include auxiliary switches such as the LS S2C-H6-11R or the S2C-S/H6R (1 changeover contact for LS and FI), as well as the Si-automat S200 B+ LS S2C-H6-20R. These components can be used for signal transmission, remote control, or integration into larger switching systems. The locking device enables secure mechanical locking of the switch, e.g., to prevent accidental switching on.

Mounting and Installation
Mounting is done on DIN rail, enabling quick and secure fastening in standard distribution boxes. The mounting dimensions are standardized, so the switch fits into common distribution boxes. The connection terminals are designed for conductor cross-sections up to 25 mm², allowing both single-core and multi-core conductors to be connected. The positioning of the neutral conductor on the left must be considered during planning of the switching system.

Advantages in Operation
The circuit breaker provides reliable protection against electrical hazards caused by fault currents. The Type A design ensures detection of pulsating direct fault currents, which is important for modern electronic loads. Compliance with standards IEC/EN 61008-1 and 61543 as well as UL 1053 ensures worldwide usability. The integrated locking device increases safety during maintenance work. The compact design and DIN rail mounting simplify installation and maintenance in distribution boxes.

Residual current circuit breaker, Type A, DIN rail, IP20, IEC/EN 61008-1