Further information for ABB 2CSF202101R1250 RCD 2-pole 25A
General
Number of poles
2
Rated current
25
Rated impulse withstand voltage Uimp
4
Mounting method
DIN rail
Leakage current type
A
Frequency
50/60 Hz
Degree of protection (IP)
IP20
Width in number of modular spacings
2
Built-in depth
69
Ambient temperature during operating
55
Pollution degree
2
Connectable conductor cross section multi-wired
25
Connectable conductor cross section solid-core
25
Depth of device
69
Height of device
85
Power loss
2
RAL-number (akin)
7035
Width of device
35
Selective protection
Short-time delayed tripping
Additional equipment possible
With interlocking device
Explosion-proof
The residual current circuit breaker F202 A-25/0.03 from ABB is a 2-pole circuit breaker for installation in electrical installations. It provides protection for persons, installations, and against fires that may be caused by electrical faults. The breaker is designed for use in household, commercial, and industrial applications and complies with standards IEC/EN 61008-1, 61008-2-1, and 61543 (equivalent to VDE 0664-10, -11, -30). It is also approved for F200 A breakers up to 100 A according to UL 1053, enabling worldwide application.
Residual current circuit breaker (RCCB) of this series protects against earth faults in sinusoidal alternating currents and in pulsating currents with a smooth direct current fault component up to 6 mA. The breaker provides fault protection (protection against indirect contact), additional protection (at a rated residual current IΔn = 30 mA), and fire protection (at IΔn = 300 mA). The protection functions are defined according to DIN VDE 0100-410 and DIN VDE 0100-530.
Residual current type A means that the breaker can detect and interrupt direct current components in the fault current, which is important for applications with electronic devices or lighting with electronic ballasts. The breaker is non-selective and not time-delayed, meaning it trips immediately upon detection of a fault current, without delay or selective tripping relative to downstream breakers.
Technology explained simply: The breaker is mounted on a DIN rail and is designed for an operating ambient temperature up to 55 °C. The protection rating IP20 protects against contact with fingers and against solid foreign objects, but is not suitable for outdoor use or in damp environments. The device dimensions are 35 mm (width), 85 mm (height), and 69 mm (depth), with the width corresponding to 2 module units. The mounting depth is 69 mm. The power loss is 2 W.
Compatibility and accessories: The breaker can be combined with various accessories to integrate additional functions. These include auxiliary switches such as the S2C-S/H6R (1 changeover contact) or the LS S2C-H6-11R, which can be used for signal input and output. Suitable phase separators such as the PS4/58N 10 mm² or the busbar PS4/12NA 10 mm² are suitable for connection with other devices in the F202 and S200 series. The connection cross-sections for single-core and multi-core conductors are each 25 mm².
Mounting and installation: The breaker is mounted on a DIN rail, with a locking device available to enhance operational safety. Installation takes place in enclosures or distribution boards that meet the requirements of the relevant standards. Pollution degree 2 is intended for environments with low pollution, such as indoor spaces without dusty or damp conditions.
Operational advantages: The combination of fast tripping in the event of a fault current, compact design, and the ability to integrate additional equipment makes the F202 A-25/0.03 a versatile device for standard installations. The color corresponds approximately to RAL 7035, enabling visual harmonization in distribution boards. Frequency readiness for 50/60 Hz ensures use in various countries.