Further information for ABB Automation 2CSB204101R1400 DDA204 A-40/0.03 FI block
General
Nominal voltage
400
Nominal current
40
Number of poles
4
Leakage current type
A
Rated insulation voltage Ui
500
Rated impulse withstand voltage Uimp
4
Connectable conductor cross section multi-wired
16
Degree of protection (IP)
IP2X
Pollution degree
2
Ambient temperature during operating
50
Power loss
4.8
Rated fault current adjustable
Delay adjustable
Anti-nuisance tripping version
With interlocking device
The ABB FI module type DDA204 A-40/0.03 is a residual current device (RCU) for customer-side mounting on circuit breakers of the S200 and S300 series. It serves as the basis for FI/LS combinations (RCBOs), ensuring personal and property protection as well as fire protection in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. The device is designed for use in residential, commercial, and industrial applications and protects circuits with 1P+N, 2P, 3P, 3P+N, or 4P wiring against overload, short-circuit currents, and fault currents. It complies with product standard IEC/EN 61009 Annex G and provides protection against sinusoidal alternating currents and pulsating currents with a smooth direct fault current component up to 6 mA to earth. Additionally, fault protection (protection against indirect contact) is provided with a rated residual current of 30 mA and fire protection with 300 mA.
Applications
The FI module is designed for use in electrical installations where combined protection against electrical hazards and fires is required. It is used in residential buildings, commercial facilities, and industrial plants, where it is mounted on circuit breakers of the S200 and S300 series. The combination of FI module and MCB creates an RCBO that integrates the functions of a circuit breaker and a residual current circuit breaker. The application is in switchgear where protection functions as required by the mentioned VDE standards are necessary.
Functions and Equipment in Detail
The device has a pole count of 4 and is rated for a nominal voltage of 400 V and a nominal current of 40 A. The residual current type is A, meaning it can detect both alternating and pulsating direct fault currents. The rated insulation voltage is 500 V, and the rated impulse voltage withstand is 4 kV. The maximum ambient temperature during operation is 50 °C. The power loss is 4.8 W. The device is equipped with a locking mechanism that enables secure mounting and locking onto the circuit breaker. It does not include a false tripping protection, and the delay time and rated residual current are not adjustable.
Technology Explained Simply
The FI module operates as an add-on module mounted onto a circuit breaker (MCB) to extend its functionality with residual current protection. The nominal voltage of 400 V and nominal current of 40 A define the electrical limits within which the device can be safely operated. The rated insulation voltage of 500 V ensures electrical insulation under operating conditions. The impulse voltage withstand of 4 kV protects the device against transient voltage surges. The locking mechanism ensures the FI module is securely attached to the MCB and cannot be accidentally released. The protection class IP2X protects against contact with fingers and larger objects, but is not waterproof.
Compatibility and Accessories
The FI module is specifically designed for mounting on circuit breakers of the S200 and S300 series. The combination results in RCBOs with different rated breaking capacities: 6 kA for S200, 10 kA for S200 M, and 25 kA for S300 P. Compatible accessories include various phase bar models such as PS3/60A, PS3/39/16 ILTS-E, PS1/57-S9, PS3/11, PS4/60/16, PS3/12A, PS3/48/16H PRO M Compact, PS4/12, PS3/60/16A, PS1/60A, PS2/58/30, PS-END3.1, AST25/15S, AST50/18U, PS4/58/16N, PS3/9H, PS4/58/16NA, and PS1/57NA. These bars and terminals enable flexible and secure wiring in switchgear. The end caps PS-END3.1 and PS-END 2CDL200001R0001 are used for finishing the bars.
Mounting and Installation
Mounting is done by attaching the FI module to a suitable circuit breaker of the S200 or S300 series. The locking mechanism ensures secure fastening. The connection cross-sections for multi-strand conductors are up to 16 mm². Installation is carried out in switchgear, where electrical and mechanical requirements of standards DIN VDE 0100-410 and DIN VDE 0100-530 must be observed. The protection class IP2X requires mounting in enclosed switch cabinets to prevent mechanical damage and contact hazards.
Advantages in Operation
The combination of FI module and MCB reduces the number of components required in the switchgear and simplifies installation. The integrated protection against fault currents and fires increases the safety of the installation. The locking mechanism ensures secure mounting, and the power loss of 4.8 W is within the typical range for such devices. Compatibility with the S200 and S300 series allows flexible adaptation to different requirements for breaking capacity. Compliance with standard IEC/EN 61009 Annex G ensures reliability and safety of the device during operation.