ABB 2CDS273061R0607, EAN: 4013614435546

ABB Automation 2CDS273061R0607 circuit breaker S203M-K63UC

Installation > Modular devices / equipment installation > Circuit breaker

ABB Automation 2CDS273061R0607 circuit breaker S203M-K63UC

Lieske Part No. 188007
Mfg Part No 2CDS273061R0607
EAN-Code 4013614435546
Manufacturer ABB
Here only 558,60 EUR
664,73 EUR incl. VAT

Further information for ABB Automation 2CDS273061R0607 circuit breaker S203M-K63UC

General
Release characteristicK
Number of poles (total)3
Number of protected poles3
Rated current63
Rated voltage400
Rated insulation voltage Ui440
Rated impulse withstand voltage Uimp4
Rated short-circuit breaking capacity Icn EN 60898 at 230 V10
Voltage typeAC/DC
Frequency60
Current limiting class3
Over voltage category3
Pollution degree3
Width in number of modular spacings3
Built-in depth69
Degree of protection (IP)IP20
Ambient temperature during operating55
Connectable conductor cross section multi-wired25
Connectable conductor cross section solid-core35
Power loss15.78
Concurrently switching N-neutralno
Additional equipment possibleyes
Explosion-proofno
Flush-mounted installationno
The circuit breaker S203M-K63UC from ABB belongs to the S 200 M UC series and is designed for protecting cables and lines against overload and short circuit. It is intended for use in electrical installations and complies with relevant standards, including DIN VDE 0100-430, DIN VDE 0100-530, DIN VDE 0641-11, as well as IEC/EN 60898-1 and IEC/EN 60947-2. The K tripping characteristic ensures targeted response to overloads, with the breaker tripping at current values above the rated current of 63 A. The rated voltage is 400 V, and the breaker is suitable for both alternating and direct current (AC/DC), making it applicable for various uses in industrial and commercial environments.

Applications
This circuit breaker is intended for use in indoor electrical distributions, particularly in enclosures and distribution boxes. It is not designed for flush mounting but for installation in row distributors or switchboards. The protection rating IP20 provides protection against finger contact and solid foreign objects, but not against splashing water or dust — thus, it is suitable exclusively for dry indoor environments. The ambient temperature during operation must not exceed 55 °C, requiring use in heated or temperature-controlled rooms.

Functions and Equipment in Detail
The breaker features a patented connection terminal that enables secure and easy connection. The connection is made via a pressure plate that securely holds the conductor. The connection opening for the conductors is positioned above the connection opening for the phase bar, simplifying wiring and improving visibility. The terminal allows direct connection of conductors with a cross-section up to 35 mm² (single-strand) or 25 mm² (multi-strand), with insulation remaining intact in the terminal area. The mounting depth is 69 mm, and the breaker occupies a width of 3 module units, making it suitable for standard distribution boxes.

Technology Explained Simply
The rated insulation voltage Ui is 440 V, and the rated impulse voltage withstand Uimp is 4 kV, describing the electrical strength of the device under transient voltage surges. The switching capacity Icn according to EN 60898 at 230 V is 10 kA, indicating the breaker’s ability to interrupt short-circuit current. The energy limitation class 3 and overvoltage category 3 indicate high safety under transient voltage surges. Pollution degree 3 indicates suitability for environments with heavy contamination, such as industrial facilities, provided no conductive substances are present.

Compatibility and Accessories
To extend functionality, additional components such as series terminals (e.g., CMS-101PS or CMS-102PS) can be used, enabling secure and quick connections between multiple breakers. These accessories are specifically developed for the S 200 M UC series and ensure a stable electrical connection. Combining them with these terminals is particularly advantageous when installing multiple breakers in a distribution box.

Mounting and Installation
The breaker is installed in row distributors or switchboards. Mounting is done using the integrated mounting guide, ensuring secure fastening. The connection terminal allows direct connection without additional tools, with the pressure plate securely holding the conductor. Wiring is done via the upper connection opening, improving work efficiency and clarity during installation.

Advantages in Operation
The S203M-K63UC features high short-circuit breaking capacity, making it suitable for applications with high current loads. The patented connection terminal reduces installation time and increases connection reliability. Compatibility with AC and DC applications expands its range of use. Compliance with standards DIN VDE 0641-11 and IEC/EN 60898-1 ensures conformity with applicable construction and safety regulations. Each device is intensively tested three times before delivery to guarantee quality and performance.