| General |
| Device fitting | Miniature circuit breaker (MCB) |
| Number of contacts as normally open contact | 1 |
| Number of contacts as normally closed contact | 1 |
| Number of contacts as change-over contact | 0 |
| Number of fault-signal switches | 0 |
| Function | Auxiliary switch |
The ABB circuit breaker auxiliary switch type S2C-H6-11R is a plug-in device for indicating the switching position of circuit breakers. It is specifically designed for right-side mounting on corresponding switches and serves for visual monitoring of the position of the device contacts, i.e., whether the switch is turned on (closed) or off (open). The function as an auxiliary switch enables integration into control and monitoring systems, where the switching position is transmitted via electrical contacts.
Auxiliary switches are common in electrical installations to transmit the state of a main device, here a circuit breaker, to other devices or systems. The S2C-H6-11R features a
number of contacts as closers of 1 and a
number of contacts as openers also of 1. This configuration enables the control of signals, for example for an indicator light or relay output, depending on whether the main switch is closed or open.
Function and
application: The auxiliary switch is mounted directly on the circuit breaker, where the mechanical connection transmits the switching position of the main device. The indication is achieved via the electrical switching position of the contacts, which can be used in a control circuit. This is particularly important in industrial plants, emergency shutdowns, or systems with remote monitoring, where visual or electrical confirmation of the switching position is required.
Technology explained simply: The auxiliary switch operates mechanically in sync with the main device. When the circuit breaker is turned on, the auxiliary switch closes its closer contact and opens its opener contact. Conversely, when the main device is turned off, the auxiliary switch closes its opener contact and opens its closer contact. This function enables integration into monitoring systems without requiring additional sensors or electronic components. The mechanical coupling ensures reliable signal transmission that directly responds to the movement of the switch.
The designation “LS S2C-H6-11R” indicates use within the ABB product range, particularly in combination with S2C switches.
Mounting and installation: Mounting is done directly on the circuit breaker, with the auxiliary switch installed on the right side. The mechanical connection is achieved via an integrated coupling that transmits the movement of the main device. Installation typically requires no additional electrical or mechanical adjustments, as the auxiliary switch is specifically designed for use with circuit breakers.
Advantages in operation: Integrating an auxiliary switch enables simple and reliable monitoring of the switching position. In plants with multiple switches or in systems requiring remote monitoring, this reduces the need for additional sensors. The mechanical coupling ensures direct and immediate response to switching operations, minimizing signal delay. Use in combination with other control or signaling devices is possible, as the contacts are designed for controlling external loads.
Batteries are not included in the delivery scope.