ABB 2CDL230004R1012, EAN: 4016779517416

ABB Automation 2CDL230004R1012 PS3/12-E463 busbar 3-phase

Installation > Distributor Cabinets > Wall, Stand, distribution systems

ABB Automation 2CDL230004R1012 PS3/12-E463 busbar 3-phase

Lieske Part No. 273502
Mfg Part No 2CDL230004R1012
EAN-Code 4016779517416
Manufacturer ABB
Here only 32,74 EUR
38,96 EUR incl. VAT

Further information for ABB Automation 2CDL230004R1012 PS3/12-E463 busbar 3-phase

General
Number of phases3
Number of poles12
Suitable for number of devices4
Pitch dimensions44698
Cross section10
Length200
Rated permanent current Iu63
Type of electric connectionPin
Max. rated operation voltage Ue690
Rated short-time withstand current lcw25
ColourGrey
Width in number of modular spacings12
Insulatedyes
Suitable for devices with N-busbarno
Suitable for devices with auxiliary switchno
The ABB phase bar series PS3/12-E463 is a modular system for safe and economical cross-wiring of circuit breakers, residual current protective devices, and other modular installation devices in distribution and meter enclosures. With a pole count of 12 and a width of 12 module units, the bar is specifically designed for use in compact distribution systems requiring high device density. The bar is rated for a maximum nominal operating voltage of 690 V and features a nominal continuous current Iu of 63 A, making it suitable for medium to high loads in industrial and commercial installations. The electrical connection is made via pin terminals, ensuring a secure and reliable connection. The bar is insulated, providing enhanced safety during installation and maintenance. The bar is grey in colour, enabling visual harmonisation with other components in the distribution system.

Applications

The PS3/12-E463 is designed for use in distribution and meter enclosures, particularly in systems requiring modular installation of switching and protective devices. It is suitable for installations with up to four devices, where the devices must have a phase count of 3. The bar is not designed for devices with a neutral conductor or auxiliary switches, which must be considered during installation planning. It is used in systems requiring stable and reliable power distribution across multiple modules, such as industrial controls, lighting systems, or building technology.

Functions and Equipment in Detail

The phase bars enable efficient and safe power distribution within the distribution system. The cross-section size of 10 mm² ensures sufficient current-carrying capacity for the specified rating. The bar length is 200 mm, corresponding to the standard length for 12 modules. The bar is rated for a short-time withstand current Icw of 25 kA, ensuring high mechanical and thermal stability during short-circuit events. The insulated design protects against accidental contact and reduces the risk of short circuits. The pin terminals allow for simple and secure mounting of devices.

Technology Explained Simply

The phase bars serve as a central power distribution unit within a distribution system. They are responsible for conducting power from the main supply to individual switching and protective devices. The insulation of the bar protects against electrical hazards and ensures safe handling. The pin terminals are designed to create a firm and permanent connection to the devices without requiring additional tools or connectors. The short-time withstand current rating of 25 kA means the bar can withstand high current levels for a short duration without damage, which is critical for safety in fault conditions.

Compatibility and Accessories

The PS3/12-E463 is specifically designed for devices with 3 phases and is suitable for a maximum of four devices. The bar is not compatible with devices incorporating a neutral conductor or auxiliary switches. Its use is intended in systems with modular installation devices, such as circuit breakers or residual current protective devices. The bar is part of the ABB Pro M Compact system and can be used in combination with other components of this system to create a uniform and structured distribution solution.

Mounting and Installation

Installation takes place in a distribution or meter enclosure, where the bar is inserted into the designated mounting elements. Devices are connected to the bar via pin terminals. The insulation of the bar simplifies installation, as no additional insulation measures are required. The length of 200 mm corresponds to the standard size for 12 modules, enabling direct mounting without additional adjustments. Installation is typically performed by qualified personnel familiar with electrical regulations.

Operational Advantages

The PS3/12-E463 provides reliable and safe power distribution within the distribution system. The insulated design and high short-time withstand current rating increase operational safety. The modular construction allows flexible adaptation to different requirements. The use of pin terminals reduces installation time and increases connection reliability. The bar is designed for long service life and requires no special maintenance, provided the installation complies with regulations.