Further information for ABB Automation 2CCS800900R0211 S800-SOR250 earth leakage circuit breaker 250 V AC/DC
General
Rated control supply voltage Us at AC 50HZ
250
Rated control supply voltage Us at AC 60HZ
250
Rated control supply voltage Us at DC
250
Suitable for power circuit breaker
Suitable for off-load switch
Suitable for motor safety switch
Suitable for overload relay
The S800-SOR250 operating current trip unit from ABB is a specific accessory module for the S800 high-performance circuit breaker. It enables remote tripping of the switch via an electrical impulse, allowing the disconnection of the circuit to be controlled from a remote location. This is particularly important in industrial plants, emergency shutdowns, or automation systems, where manual operation is not possible or not safe. The trip unit is designed for operating voltages of 250 V AC (50 Hz and 60 Hz) as well as 250 V DC and ensures reliable operation when the actual voltage is between 70 % and 110 % of the nominal network voltage Un. This voltage tolerance range ensures stable function even with voltage fluctuations in the network.
Applications
The S800-SOR250 is primarily used in installations where the S800 high-performance circuit breaker serves as a power switch. It is specifically designed for remote control of switching-off operations, for example in production plants, safety shutdowns, or systems with integrated monitoring. Compatibility with power switches makes it a suitable component in industrial electrical installations where fast and reliable disconnection is required. Use in load switches or motor protection switches is not intended according to the manufacturer's specifications.
Functions and Equipment in Detail
The operating current trip unit operates via an electrical impulse triggered by an external control device or an automation control system. This impulse causes the mechanical tripping of the switch, thereby interrupting the circuit. Operational safety is ensured by the defined voltage tolerance range of 70 % to 110 % of the nominal network voltage Un, regardless of whether the supply voltage is alternating or direct current. The design for 250 V AC/DC makes the trip unit suitable for a wide range of industrial applications, particularly in systems operating with medium voltages.
Technology Explained Simply
The trip unit uses electrical energy from the network to activate the tripping function. The rated control supply voltage is 250 V, both for alternating and direct voltage. The function is independent of frequency (50 Hz or 60 Hz) for alternating voltage. Tripping is triggered by an external impulse applied to the trip unit via a control cable. The technical design ensures that the trip unit only functions within the defined voltage range (70 % to 110 % of the nominal network voltage), preventing false tripping at excessively low or high voltages.
Compatibility and Accessories
The S800-SOR250 is specifically designed for use with the S800 high-performance circuit breaker. It is suitable for power switches and can be combined with overload relays to integrate additional protection functions. Use in load switches or motor protection switches is not intended according to the manufacturer's specifications. Compatibility with other ABB products in the S800 portfolio is provided, especially in systems requiring remote control functions.
Mounting and Installation
Mounting is carried out directly on the S800 high-performance circuit breaker. The trip unit is integrated into the device, with electrical connections made to the control wiring. Installation requires no additional tools or components, as the trip unit is designed as a modular accessory. Wiring is carried out according to the technical instructions for the respective circuit breaker, taking into account voltage tolerance and impulse control.
Advantages in Operation
The use of the S800-SOR250 enables safe and reliable remote disconnection, which is particularly advantageous in critical installations. The function is independent of frequency and applies to both alternating and direct voltage, increasing its applicability in various systems. The defined voltage tolerance ensures that the trip unit is only activated at safe operating voltage, avoiding false alarms and unintended disconnections. Integration into existing S800 systems requires no additional components, simplifying installation and maintaining system integrity.