ABB 2CCS571001R0377, EAN: 7612270101665

ABB Automation 2CCS571001R0377 S401M-K6 circuit breaker K

Installation > Modular devices / equipment installation > Circuit breaker

ABB Automation 2CCS571001R0377 S401M-K6 circuit breaker K

Lieske Part No. 300442
Mfg Part No 2CCS571001R0377
EAN-Code 7612270101665
Manufacturer ABB
Here only 39,80 EUR
47,36 EUR incl. VAT

Further information for ABB Automation 2CCS571001R0377 S401M-K6 circuit breaker K

General
Release characteristicK
Number of poles (total)1
Number of protected poles1
Rated current6
Rated voltage240
Rated insulation voltage Ui440
Rated impulse withstand voltage Uimp4
Rated short-circuit breaking capacity Icn EN 60898 at 230 V10
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V25
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V25
Voltage typeAC
Frequency60
Current limiting class3
Over voltage category3
Pollution degree3
Width in number of modular spacings1
Built-in depth75
Degree of protection (IP)IP20
Ambient temperature during operating60
Connectable conductor cross section multi-wired25
Connectable conductor cross section solid-core35
Power loss1.7
Concurrently switching N-neutralno
Additional equipment possibleyes
Explosion-proofno
Flush-mounted installationno
The circuit breaker S401M-K6 from ABB belongs to the S 400 series and serves the protective function for cables and lines against overload and short circuit. It is designed for use in electrical installations and complies with relevant standards, including DIN VDE 0100-430, DIN VDE 0100-530, DIN VDE 0641-11, as well as IEC/EN 60898-1 and IEC/EN 60947-2. The K tripping characteristic ensures targeted response to overloads in the range of 5 to 10 times the rated current, thereby optimizing the protective function for electrical systems with medium loads.

Applications

The switch is intended for indoor use, as it features protection class IP20, which provides protection against contact with fingers and against solid foreign objects up to 12.5 mm in diameter. The ambient temperature during operation is up to 60 °C, making it suitable for typical installation environments in buildings. It is not intended for flush mounting and is installed in modular enclosures, with an installation depth of 75 mm.

Functions and Equipment in Detail

The S401M-K6 features a patented connection terminal that enables simple and secure connection. The terminal is operated via a pressure plate, simplifying installation and maintenance. Directly at the terminal, conductor cross-sections up to 35 mm² (single-strand) and 25 mm² (multi-strand) can be connected, with insulation integrated into the device. Connection is made via the plug-in socket system, and the external conductor connection can be freely selected between L1, L2, or L3. The width is one module unit, making it suitable for standard installation enclosures.

Technology Explained Simply

The switch is rated for a nominal voltage of 240 V AC, with a nominal insulation voltage Ui of 440 V. The nominal impulse voltage withstand Uimp is 4 kV, indicating the device’s ability to withstand short-term voltage surges. The nominal switching capacity Icn is 10 kA at 230 V, while the Icu value is 25 kA at both 230 V and 400 V. These values define the maximum current the device can safely interrupt. Energy limitation class 3 indicates that the switch limits energy development during a short circuit. Overvoltage category 3 and pollution degree 3 refer to the environmental conditions under which the device can be safely operated.

Compatibility and Accessories

Additional functions can be implemented using auxiliary devices, with compatible accessories such as auxiliary switches (e.g. HK40020-R or HK40020-L) or sensors (e.g. CMS-122PS Open-Core sensors 20 A) available. These components extend the functionality of the switch, for example for remote monitoring or signaling. Combination with other components is achieved via the plug-in socket system, enabling modular expansion.

Installation and Mounting

Mounting is carried out in modular enclosures using the plug-in socket. The installation depth of 75 mm must be considered when planning the enclosure depth. The connection terminal allows direct connection of conductors, with insulation integrated into the device. The power loss is 1.7 W, describing the thermal load during operation.

Operational Advantages

The S401M-K6 provides reliable protection for electrical systems. The patented connection terminal and plug-in socket system simplify installation and maintenance. Compliance with standards DIN VDE 0641-11, IEC/EN 60898-1, and IEC/EN 60947-2 ensures conformity with applicable construction and safety regulations. The IP20 protection class and specified environmental conditions make it suitable for indoor use. The high switching capacity and energy limitation class 3 enhance safety during short-circuit events.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/300442
qrcode für ABB Automation 2CCS571001R0377 S401M-K6 circuit breaker K