Further information for ABB 1SVR500130R0000 CT-VWD.12 Time Relay On-Off
General
Type of electric connection
Screw connection
Rated control supply voltage Us at AC 50HZ
240
Rated control supply voltage Us at AC 60HZ
240
Rated control supply voltage Us at DC
48
Voltage type for actuating
AC/DC
Nominal current
6
Time range
360000
Number of outputs, undelayed, normally closed contact
0
Number of outputs, undelayed, normally open contact
0
Number of outputs, undelayed, change-over contact
0
Number of outputs, delayed, normally closed contact
0
Number of outputs, delayed, normally open contact
0
Number of outputs, delayed, change-over contact
0
Width
17.5
Height
70
Depth
63
Degree of protection (IP)
IP20
Operating voltage at AC 50 Hz
250
Operating voltage at AC 60 Hz
250
Voltage type (operating voltage)
AC/DC
Function delay-on energization
Function delay on de-energization
Function floating contact on energization
Function floating contact on de-energization
Function star-delta
Function pulse shaping
Function flashing, starting with pause, fixed time
Function flashing, starting with pulse, fixed time
Clock function, starting with pause, variable
Clock function, starting with pulse, variable
Remote operation possible
Suitable for remote control
Pluggable on auxiliary contact block
Outputs, reversible delayed/undelayed
With semiconductor output
Suitable for DIN rail (top hat rail) mounting
Complete with socket
Front mounting
The ABB time relay type CT-VWD.12 is a single device in MDRC design, specifically designed for use in installation and distribution enclosures. It features a compact housing with a width of 17.5 mm, which can be integrated into standardised control systems and distribution boxes without additional modifications. The CT-D series represents a connection between industrial and installation design forms and is suitable for various applications in the field of electrical control and automation. The device is designed as on-delay, meaning that it switches immediately upon activation of the input and initiates a delay until the contact returns after switching off. This function is typical for applications requiring a short delay when switching off, for example in lighting systems or motor controls.
Applications
The time relay CT-VWD.12 is intended for use in electrical controls in the installation sector, particularly in systems requiring time-controlled switching functions. It is suitable, for example, for stairway lighting systems, where the lighting continues for a certain period after a switch is activated, or for controlling pumps, fans and other consumers that require a short delay after switching off. The design allows for mounting on a DIN rail, which facilitates integration into existing enclosures. The MDRC design ensures a compact and standardised mounting solution used in many European and international distributors.
Functions and Equipment in Detail
The device features a wide voltage input, supporting an operating voltage of 250 V AC at 50 Hz and 250 V AC at 60 Hz. Additionally, it is suitable for a direct voltage of 48 V DC, enabling flexible use under various network voltage conditions. The rated control supply voltage is 240 V AC at 50 Hz and 240 V AC at 60 Hz, as well as 48 V DC. The operating voltage is thus suitable for a wide range of applications, including international deployment. The device is equipped with a screw connection, ensuring a secure and mechanically stable connection. The rated current is 6 A, which is sufficient for most standard applications in the installation sector.
Technology Explained Simply
The on-delay function means that the relay reacts immediately upon switching on and performs the switching function. Upon switching off, a delay occurs until the contact returns. This delay is adjustable and can range from 0.05 seconds to 100 hours depending on the application. The time range of 360000 seconds corresponds to 100 hours, offering high flexibility in setting the delay time. The protection rating IP20 protects the device against contact with fingers and against solid foreign objects, but not against splashing water or dust. The device is therefore suitable for indoor use, but not for outdoor or damp environments.
Compatibility and Accessories
The time relay is designed for mounting on a DIN rail, enabling easy integration into existing enclosures. It is not designed to be mounted on contactors and does not feature remote control functionality. The CT-D series offers a total of 10 single and 2 multifunction devices with 7 different time functions, including the on-delay function of the CT-VWD.12. The devices are available in various time ranges, with the current model supporting a time range from 0.05 seconds to 100 hours. The voltage type AC/DC allows use under various network voltage conditions, ensuring worldwide applicability.
Mounting and Installation
Mounting is done via a DIN rail, which is standard in most installation and distribution enclosures. Mechanical fixation is achieved by inserting the device into the rail, while electrical connections are made via screw terminals. The connection terminals are designed for secure connections and allow for simple and reliable wiring. The dimensions of the device are 17.5 mm (width), 70 mm (height), and 63 mm (depth), enabling compact placement in tight control systems.
Advantages in Operation
The ABB CT-VWD.12 offers high flexibility through its adjustable time range from 0.05 seconds to 100 hours, making it suitable for a wide range of applications. The use of a wide voltage input enables worldwide applicability without additional modifications. The MDRC design ensures a compact and standardised mounting solution used in many distributors and enclosures. The screw connections ensure a secure and mechanically stable connection, increasing reliability in operation. The protection rating IP20 is sufficient for use in dry indoor environments and meets common requirements in the installation sector.