Further information for ABB Automation 1SAM250000R1001 motor protection switch MS116-0.16
General
Overload release current setting
0.16
Adjustment range undelayed short-circuit release
2
Switch off technique
Thermomagnetic
Rated operating voltage
690
Rated permanent current Iu
0.16
Rated operation power at AC-3, 230 V
0.03
Rated operation power at AC-3, 400 V
0.03
Type of electrical connection of main circuit
Screw connection
Type of control element
Other
Device construction
Complete device in housing
Number of poles
3
Rated short-circuit breaking capacity lcu at 400 V, AC
100
Degree of protection (IP)
IP20
Height
90
Width
45
Depth
85.6
Power loss
5.1
With thermal protection
Phase failure sensitive
With integrated auxiliary switch
With integrated under voltage release
The ABB motor protection switch type MS116-0.16 is a compact switching system for electrical protection of motors in industrial applications. It is part of the MS116 series, designed for economical and space-saving installations, particularly in enclosures and distributions. The switch features a thermal and electromagnetic tripping mechanism, enabling it to detect overloads and short circuits and disconnect safely. The current setting of the overload tripping unit is 0.16 A, with the instantaneous short-circuit tripping range being 2 times. The tripping technology is thermomagnetic, combining thermal response to sustained overload and magnetic response to sudden current surges. The device is rated for a nominal operating voltage of 690 V and has a nominal continuous current Iu of 0.16 A. The nominal operating power is 0.03 kW at 230 V and 400 V (AC-3). The protection class IP20 ensures protection against finger contact and solid foreign objects, but not against water or dust – suitable for indoor installations. Dimensions are 90 mm (height), 45 mm (width), and 85.6 mm (depth). The power loss is 5.1 W.
Applications
The motor protection switch is designed for use in industrial plants where motors up to a power of 15 kW (at 400 V) must be protected. It is particularly suitable for applications in manufacturing, process engineering, and building automation, where a reliable and compact protection solution is required. The module width of 45 mm enables efficient space utilisation in enclosures. The device is designed for use in 3-phase networks, with a pole count of 3. The rated short-circuit breaking capacity Icu at 400 V, AC is 100 kA, ensuring high safety in the event of short circuits.
Functions and Equipment in Detail
The switch features a rotary handle operation with a clear switching position indicator I/0, visually showing the operating status. The rotary handle can be locked in the 0 position using a locking device, preventing unintended switching on. The device is temperature-compensated, meaning the thermal tripping function operates independently of ambient temperatures. The main circuit connection is via screw terminals. There is no integrated auxiliary switch or undervoltage release, but auxiliary and signal contacts, as well as undervoltage and operating current releases, can be installed without tools. This allows for flexible expansion of functionality according to requirements.
Technology Explained Simply
The thermal protection function responds to continuous overload by deforming a bimetal strip due to heat, which triggers the switch to trip. The electromagnetic function responds to sudden current surges, such as those occurring during short circuits, and trips the switch immediately. The combination of both technologies ensures comprehensive protection. The temperature-compensated design ensures that the thermal response is not influenced by ambient temperature, increasing reliability. The IP20 protection class is suitable for indoor environments where no direct exposure to water or dust is expected.
Compatibility and Accessories
Various accessories are available for this motor protection switch, extending its functionality. These include interlock mechanisms with and without coding (MSMN, MSMNO), which can be used for mechanical interlocking of multiple switches. A padlock with two keys (SA2 GJF1101903R0002) enables additional securing of the switch position. The MS116 series also supports 3-phase rails for 65 A and 100 A, as well as feed blocks for 25 mm² and 35 mm², enabling common feeding of multiple switches. Protection enclosures and accessories for enclosure and door mounting complete the range.
Mounting and Installation
The switch is connected via screw terminals in the main circuit. Mounting is done in enclosures or distributions, with the module width of 45 mm enabling compact placement. The rotary handle operation is easily accessible, and the switching position indicator I/0 facilitates visual monitoring. The locking device can be used to secure the switch in the 0 position, preventing unintended switching on. Installation of most extensions, such as auxiliary and signal contacts, can be done without tools.
Advantages in Operation
The motor protection switch provides reliable protection for motors up to 15 kW at 400 V. The thermomagnetic tripping technology ensures comprehensive protection against overload and short circuit. The temperature-compensated design increases reliability regardless of ambient temperatures. The clear switching position indicator and the ability to lock in the 0 position enhance safety. The modular design and the possibility of common feeding of multiple switches increase installation flexibility. The MS116 series is designed for economical and space-saving installation, making it suitable for many industrial applications.