ABB 1SAL100560R9906, EAN: 4013614550393

ABB Automation 1SAL100560R9906 MACL110AT auxiliary switch 1S screw connection

Industrial Material > Control devices / Pilot devices > Motor protection switch

ABB Automation 1SAL100560R9906 MACL110AT auxiliary switch 1S screw connection

Lieske Part No. 706093
Mfg Part No 1SAL100560R9906
EAN-Code 4013614550393
Manufacturer ABB
Here only 11,75 EUR
13,98 EUR incl. VAT

Further information for ABB Automation 1SAL100560R9906 MACL110AT auxiliary switch 1S screw connection

General
Number of contacts as change-over contact0
Number of contacts as normally open contact1
Number of contacts as normally closed contact0
Number of fault-signal switches0
Rated operation current Ie at AC-15, 230 V6
Type of electric connectionScrew connection
ModelTop mounting
Mounting methodSide mounting
Lamp holderNone
The auxiliary switch MACL110AT from ABB is a 1-pole auxiliary contact block specifically designed for use in standard industrial environments. It is used for switching auxiliary and control circuits and is mounted laterally on MC1 and MC2 contactors that feature an integrated normally-closed auxiliary contact. The switch is designed as a snap-on unit, enabling quick and secure integration into existing control systems. It features a non-delayed normally-closed contact, ensuring reliability in control and signaling applications. Contact labeling follows the EN50012 standard, providing uniform and clear identification in industrial installations.

Auxiliary contact block

The MACL110AT is an auxiliary contact block used in industrial control systems to transmit additional signals or status information. It is not designed for main current conduction, but for signal transmission in control and auxiliary circuits. The 1-pole configuration with one normally-closed contact allows activation of relays, indicators, or other control devices as soon as the main contact of the associated contactor closes. Its use in standard industrial environments makes it suitable for a wide range of applications in manufacturing and automation technology.

Functions and features in detail

The switch features a single normally-closed contact that operates without delay. This means the contact closes immediately when the main contact of the contactor is activated, without any time lag. Contact labeling follows EN50012, enabling standardized and unambiguous identification of contacts. The screw terminal connection ensures a secure and durable connection, remaining stable even under mechanical stress or vibration. Mounting is done laterally on MC1 and MC2 contactors, allowing for compact and space-saving installation in enclosures.

Technology explained simply

The MACL110AT operates as a mechanically coupled auxiliary contact that mirrors the position of the main contact of the contactor. When the main contact closes, the auxiliary contact also closes, which can be used, for example, to activate a status indicator or another relay. Rated for an operating current of 6 A at AC-15 and 230 V, it is suitable for typical control applications. The screw terminals allow for easy and secure connection to cables, with mechanical strength supported by the snap-on mounting method. The design without a socket means no additional holders or fastening elements are required — mounting is done directly onto the contactor.

Compatibility and accessories

The auxiliary switch is specifically developed for mounting on MC1 and MC2 contactors from ABB. It is not intended for other contactor types or manufacturers. Use in combination with contactors featuring an integrated normally-closed auxiliary contact is the intended application.

Mounting and installation

Mounting is done by snapping the auxiliary switch laterally onto the corresponding contactor. The mechanical connection is firm and secure, without requiring additional fastening elements. The screw terminals allow for simple and reliable connection to control wiring. Installation requires no special tools, except a screwdriver for securing the connection cables. Positioning is typically done within the enclosure, with attention to accessibility and correct alignment of the terminals.

Advantages in operation

The MACL110AT provides reliable and maintenance-free signal transmission in industrial control systems. The non-delayed operation of the normally-closed contact ensures precise synchronization with the main contact, which is critical for control circuit functionality. The screw terminals ensure a stable electrical connection that remains reliable under industrial conditions. The compact design and lateral mounting enable efficient space utilization in enclosures. Compliance with the EN50012 standard for contact labeling simplifies planning and maintenance of the system, as the labels are uniform and clear.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

https://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/706093
qrcode für ABB Automation 1SAL100560R9906 MACL110AT auxiliary switch 1S screw connection