| Here only |
on request on request
Further information for Zander Aachen Safety switching device - SR3C 115V 50-60Hz
SR3D Safety Relay – Universal Safety Solution for Machines and Systems
The SR3D is a versatile safety relay designed to meet the highest safety requirements up to PL e and SIL 3. With its three secure, redundant relay outputs, it ensures that moving machine parts are stopped quickly and reliably in the event of a hazard. It supports single- or dual-channel emergency stop circuits as well as protective barrier monitoring.
One of the key advantages of the SR3D is its suitability for use in continuous operation in combustion plants (according to EN 50156-1 and EN 746-2) as well as on ships. Certified by TÜV Rheinland and Germanischer Lloyd, the SR3D meets the most stringent safety standards, providing comprehensive protection for both personnel and machinery. Functions and Features of the SR3D:- Two Start Modes: Monitored manual start or automatic start possible
- Safety Levels: Up to PL e and SILCL 3 in accordance with EN ISO 13849-1 and IEC 61508
- Protection Functions: Cross-fault and ground-fault monitoring for an uninterrupted safety chain
- Relay Outputs: 3 secure, redundant, and diverse relay outputs, plus 1 auxiliary contact (signaling contact)
- Reliable Monitoring: Cyclical monitoring of output contacts to detect errors
- Switch Status Indicator: LED display for quick status diagnostics
Connection Options:- Emergency Stop Buttons: Direct connection possible
- Safety Switches: For the monitoring of protective guards or access doors
- Non-Contact Safety Switches: Compatible with modern non-contact safety solutions
- Safety Components with OSSD Outputs: Direct connection to OSSD sensors
Operating Modes and Safety Mechanisms:- Single- or Dual-Channel Operation: Adaptable to various safety concepts
- Feedback Loop: Monitors downstream contactors or expansion modules to ensure functionality
- Force-Guided Relays: Internal faults do not result in a loss of the safety function, as the system detects and reports errors through cyclical self-monitoring
Simple Installation and Setup:- Mounting on 35 mm DIN Rail: Compliant with EN 60715 TH35
- Installation in Control Cabinets: Designed for control cabinets with a protection rating of IP54
- Distance Requirements: For the AC 115 V / 230 V version, a minimum distance of 10 mm from adjacent devices must be maintained. Spacers from ZANDER AACHEN (Part No. 472596) are available to ensure proper spacing.
- Heat Dissipation: Sufficient heat dissipation must be ensured in the control cabinet to avoid overheating.
Certifications and Standards:- Compliance: EN 60204-1, EN 50156-1, EN 746-2
- Certifications: TÜV Rheinland and Germanischer Lloyd
Technical Data:- Safety Levels: Up to PL e and SIL 3
- Start Behavior: Monitored manual start or automatic start
- Relay Outputs: 3 secure, redundant, diverse relay outputs and 1 auxiliary contact
- Connection Options: Emergency stop buttons, safety switches, non-contact safety switches, safety components with OSSD outputs
- Monitoring: Cross-fault and ground-fault monitoring, feedback loop, cyclical monitoring of output contacts
- Mounting: On 35 mm DIN rail (EN 60715 TH35)
- Protection Class: Installation in control cabinets with protection class IP54
- Distance: Minimum distance of 10 mm for AC 115 V / 230 V version
- Accessories: Spacer (ZANDER AACHEN, Part No. 472596)