
| Lieske Part No. | 1603287 |
|---|---|
| Mfg Part No | SR3AD AC/DC 24V |
| EAN-Code | |
| Manufacturer | Zander Aachen |
| Here only | on request on request
Further information for Zander Aachen Safety switching device - SR3AD AC/DC 24VSafe and non-safe coupling relays:In the process industry, the safe transmission of safety-related signals from the controller to peripheral devices is crucial. In safety-critical control systems (e.g., emergency stop functions), signals must be transmitted safely without interrupting the safety chain. Conventional coupling relays are not suitable for this purpose, as they lack safety features and, therefore, cannot guarantee a safe shutdown of the machine or system in the event of a hazard. Safe coupling relays solve this problem. These relays are redundantly constructed and feature self-monitoring mechanisms that enable a safe and standard-compliant coupling of safety-related signals. They are certified to the highest safety standards (up to SIL 3 according to IEC 61508 and PL e according to EN ISO 13849-1), ensuring that the safety function remains intact even if an internal relay failure occurs. ### Typical applications of safe coupling relays:
### Features of safe coupling relays:
### Differences between safe and non-safe coupling relays: | Feature | Safe Coupling Relay | Non-Safe Coupling Relay | |---------------------------- |-------------------------------------|-------------------------------------| | Force-guided contacts | Yes | No | | Redundancy | Yes | No | | Self-monitoring | Yes | No | | Certified up to SIL/PL | Up to SIL 3 / PL e | No safety certification | | Galvanic isolation | Yes | Optional, not always available | | Filtering of test pulses | Yes | No | ### Advantages of safe coupling relays:
### Conclusion: Safe coupling relays are an essential component of safety-critical control systems. They ensure that safety-related control signals are transmitted to peripheral devices in compliance with standards. Thanks to force-guided contacts, self-monitoring, and certification up to SIL 3 / PL e, safe coupling relays guarantee that the safety function remains intact even if an internal fault occurs. In contrast, non-safe coupling relays provide no such guarantee and are only suitable for simple, non-safety-related applications.
This is an offer of:
Lieske Elektronik e.K.Reutener Str. 1079279 Vörstetten http://industry-electronics.com Tel. 07666/88499-0 Fax. 07666/88499-111 Diesen Artikel finden Sie unter: industry-electronics.com/artikel/1603287 |