Zander Aachen SR3A 115V 50-60Hz

Zander Aachen Safety switching device - SR3A 115V 50-60Hz

Industrial Material > Industrial relays and contactors > Safety relay

Zander Aachen Safety switching device - SR3A 115V 50-60Hz

Lieske Part No.1599707
Mfg Part NoSR3A 115V 50-60Hz
EAN-Code
Manufacturer Zander Aachen
Here only on request on request

Further information for Zander Aachen Safety switching device - SR3A 115V 50-60Hz

SR3D Safety Control Device – Universal, Safe, and Reliable

The SR3D is a universal safety control device with three safe relay outputs that ensures the fast and safe shutdown of moving parts of a machine or system in the event of danger. It is specifically designed for use in continuous operation of firing systems in accordance with EN 50156-1 and EN 746-2, as well as for use on ships, for which it has been certified by TÜV Rheinland and Germanischer Lloyd.

---

### Key Features of the SR3D
  • Two start modes available:
  • - Monitored manual start
    - Automatic start
  • Cross-fault and ground-fault monitoring
  • Use up to PL e, SILCL 3, Category 4 – Meets the highest safety requirements

---

### Technical Functions of the SR3D
  • 3 safe relay outputs (redundant and diverse)
  • 1 auxiliary contact (signal contact) for status indication
  • Force-guided relays for maximum operational safety
  • Cyclic monitoring of relay contacts – Ensures that the safety function is maintained even in the event of internal faults
  • Feedback circuit to monitor downstream contactors or expansion modules
  • Status display via LED – Clear visualization of the switching states

---

### Connection Options
The SR3D allows direct connection of the following devices:
  • Emergency stop buttons
  • Safety switches
  • Contactless safety switches
  • Safety components with OSSD outputs

This flexibility makes the SR3D ideal for a wide range of machines and systems requiring diverse safety requirements.

---

### Application Areas of the SR3D
  • Emergency stop circuits (single- or dual-channel)
  • Protective guard monitoring on machines and systems
  • Control of firing systems
  • Ship applications (certified by Germanischer Lloyd)

---

### Safety Functions in Detail
The SR3D guarantees the safe separation of safety circuits in accordance with EN 60204-1, enabling a safety stop function up to PL e / SIL 3 in accordance with EN ISO 13849-1 and IEC 61508.

  • Standard-compliant shutdown: When an emergency stop button is pressed, the release paths are immediately opened, and the machine is safely shut down.
  • Redundant relays: Even if one relay fails, the function is maintained, as the cyclic self-monitoring detects and addresses errors.

---

### Mounting Instructions
For flawless operation, the following guidelines must be observed:
  • Mounting on a 35 mm DIN rail according to EN 60715 TH35
  • Minimum protection class IP54 – Must be installed in control cabinets with sufficient heat dissipation
  • Distance from adjacent devices: For the AC 115 V / 230 V variant, a distance of at least 10 mm from adjacent devices must be maintained.

Tip: Use the ZANDER AACHEN spacer (Art. no. 472596) to ensure defined distances.

---

### Certificates and Conformity
  • EN ISO 13849-1 – Functional safety up to PL e
  • EN 50156-1 – Safety of firing systems
  • Germanischer Lloyd certificate – Approved for use on ships

---

The SR3D is the ideal choice for machine and system safety in industry, shipbuilding, and firing systems.
This is an offer of:

Lieske Elektronik e.K.

Reutener Str. 10
79279 Vörstetten

http://industry-electronics.com
Tel. 07666/88499-0
Fax. 07666/88499-111

Diesen Artikel finden Sie unter:
industry-electronics.com/artikel/1599707
qrcode für Zander Aachen Safety switching device - SR3A 115V 50-60Hz