SR3D Safety Control Unit – Reliable Safety Solution for Machines and Systems
The SR3D safety control unit ensures the safe and quick shutdown of machines and systems in the event of a hazard. With its three safe relay outputs and an auxiliary contact (monitoring contact), the device meets the highest safety standards up to PL e / SIL 3. The SR3D is versatile, from emergency stop circuits to safety guard monitoring.
Application Areas of the SR3D
The SR3D safety control unit is used in the following areas:
- Emergency stop circuits (single or dual-channel)
- Safety guard monitoring on machines and systems
- Continuous operation combustion plants according to EN 50156-1 and EN 746-2
- Maritime applications (certified by TÜV Rheinland and Germanischer Lloyd)
Key Features and Benefits
- 2 possible start behaviors:
- Monitored manual start
- Automatic start
- Operation up to: PL e, SILCL 3
- Cross-fault and ground-fault monitoring to ensure line integrity
- 3 safe, redundant, diverse relay outputs for maximum safety
- 1 auxiliary contact (monitoring contact) for status monitoring
- Connection options:
- Emergency stop buttons
- Safety switches
- Contactless safety switches
- Safety components with OSSD outputs
Functionality and Safety Concept
The SR3D ensures safe separation of safety circuits according to EN 60204-1 and fulfills the stop function requirements up to PL e / SIL 3 according to EN ISO 13849-1 and IEC 61508. If the emergency stop circuit is activated (e.g., by pressing an emergency stop button or opening a safety door), the SR3D immediately interrupts the enabling current paths and stops the machine.
Additional Safety Functions
- Force-guided relay contacts ensure that the safety function is maintained even if a fault occurs in the device.
- Cyclic monitoring of relay outputs to detect contact welding or failures.
- Feedback loop to monitor downstream contactors or expansion modules.
- LED display of switch status for quick diagnosis and maintenance.
Technical Specifications
- Protection class: IP54 (installation in control cabinets required)
- Operating voltage: AC 115 V / 230 V – Maintain a minimum distance of 10 mm to adjacent devices
- Mounting: On a 35 mm DIN rail according to EN 60715 TH35
- Climatic conditions: Ensure proper heat dissipation in the control cabinet to prevent overheating
- Distance to adjacent devices: Minimum of 10 mm for AC 115 V / 230 V version
Standards and Certifications
The SR3D meets the following safety standards and requirements:
- EN ISO 13849-1 (PL e)
- IEC 61508 (SIL 3)
- EN 60204-1 (safe separation of safety circuits)
- EN 50156-1 / EN 746-2 (for use in combustion plants)
- Certified by TÜV Rheinland and Germanischer Lloyd
Conclusion
The SR3D safety control unit is a reliable solution for the monitoring and shutdown of machines and systems in emergency stop and safety guard monitoring systems. Its redundancy, diversity, and force-guided relay contacts ensure maximum operational safety.