| Lieske Part No. | 1599662 |
|---|---|
| Mfg Part No | S2HC AC/DC 24V |
| EAN-Code | |
| Manufacturer | Zander Aachen |
| Here only | on request on request
Further information for Zander Aachen Two hand control relay - S2HC AC/DC 24V
Safety Control Device SR3D – Universal Safety Control Device with Three Secure Relay Outputs
The SR3D is a versatile safety control device that enables the safe shutdown of moving machine parts in hazardous situations. With three secure, redundant, and diverse relay outputs, the device ensures the fast and reliable stoppage of machines and systems. Typical applications include single- or dual-channel emergency stop circuits and protective guard monitoring on machinery. The SR3D is specially designed for use in combustion plants in accordance with EN 50156-1 and EN 746-2, as well as for use on ships. Certifications from TÜV Rheinland and Germanischer Lloyd confirm compliance with the highest safety standards. Thanks to its compact design, the device is ideal for use in control cabinets with a protection rating of at least IP54. Technical Data:
- Type-tested for combustion systems according to EN 50156-1 and EN 746-2 - Certified by TÜV Rheinland and Germanischer Lloyd (Certificate TAE00003JF) - 1 auxiliary contact (signal contact) for status monitoring - Emergency stop buttons - Safety switches - Contactless safety switches - Safety components with OSSD outputs (Output Signal Switching Device) - Start behavior: - Monitored manual start - Automatic start - Feedback loop for monitoring downstream contactors or extension modules - Cyclical monitoring of output contacts - Self-monitoring detects errors during the next request of the safety function - Single faults do not result in the loss of the safety function - Status display via LED - Protection class: IP54 when installed in a control cabinet - Ensure adequate heat dissipation in the control cabinet - For the AC 115 V / 230 V variant, a minimum distance of 10 mm from neighboring devices must be maintained - Recommended distance holders: ZANDER AACHEN (Part No. 472596) to maintain defined distances Functions:- When the emergency stop circuit is closed, the machine is enabled. - If the safety function is requested (e.g., by opening the safety door), the SR3D immediately interrupts the release paths, ensuring the machine is safely shut down. - Errors are detected no later than during the next request of the safety function, ensuring that single faults do not result in the loss of the safety function. Scope of Delivery:
This is an offer of:
Lieske Elektronik e.K.Reutener Str. 1079279 Vörstetten http://industry-electronics.com Tel. 07666/88499-0 Fax. 07666/88499-111 Diesen Artikel finden Sie unter: industry-electronics.com/artikel/1599662 |