| Lieske Part No. | 1603285 |
|---|---|
| Mfg Part No | S2HC AC 115V |
| EAN-Code | |
| Manufacturer | Zander Aachen |
| Here only | on request on request
Further information for Zander Aachen Two hand control relay - S2HC AC 115V
Safety Control Device SR3D – Universal Safety Relay with Three Secure Relay Outputs
The SR3D safety control device offers a flexible and reliable safety solution for safely shutting down machines and systems in hazardous situations. With three secure, redundant, and diverse relay outputs, it enables the quick stoppage of moving machine parts. Thanks to the use of forcibly guided relays and integrated self-monitoring, the highest level of safety is ensured – even in the event of a fault. The SR3D is universally applicable and is suitable for single- or dual-channel emergency stop circuits and for monitoring protective doors on machines. It is specifically designed for use in continuous operation in combustion plants in accordance with EN 50156-1 and EN 746-2, as well as for use on ships. The device is certified by TÜV Rheinland and the Germanischer Lloyd, ensuring compliance with the highest safety standards. Technical Data:
- Type-tested for combustion systems according to EN 50156-1 and EN 746-2 - Certified by TÜV Rheinland and Germanischer Lloyd (Certificate TAE00003JF) - 1 auxiliary contact (signal contact) for monitoring the switching status - Connection of: - Emergency stop buttons - Safety switches - Contactless safety switches - Safety components with OSSD outputs (Output Signal Switching Device) - Automatic start - Feedback loop for monitoring downstream contactors or extension modules - Cyclical monitoring of output contacts - Self-monitoring detects errors during the next request of the safety function - Single faults do not result in the loss of the safety function - Protection class IP54 when installed in a control cabinet - LED indicators to display the switching status - Ensure adequate heat dissipation in the control cabinet - For the AC 115 V / 230 V variant, a minimum distance of 10 mm from neighboring devices must be maintained - Recommended distance holders: ZANDER AACHEN (Part No. 472596) to maintain defined distances Functions:- When the emergency stop circuit is closed, the machine is enabled via the SR3D. - In the event of a fault or request for the safety function, the device immediately opens the release paths to safely shut down the machine. - Single faults within the device do not result in the loss of the safety function. Scope of Delivery:
This is an offer of:
Lieske Elektronik e.K.Reutener Str. 1079279 Vörstetten http://industry-electronics.com Tel. 07666/88499-0 Fax. 07666/88499-111 Diesen Artikel finden Sie unter: industry-electronics.com/artikel/1603285 |