| Here only |
on request on request
Further information for Zander Aachen SR3C DC 24V - Safety Emergency Stop Relay SR3C
The SR3C safety relay is a universally applicable device featuring three safe, redundant relay contacts and one auxiliary contact (status contact). Designed to safely shut down machinery and equipment in hazardous situations, it meets the highest safety standards up to PL e, SIL 3, and Category 4 in accordance with EN ISO 13849-1 and IEC 61508. With flexible connection options, monitoring functions, and two selectable start behaviors, the SR3C is ideal for single- or dual-channel emergency stop circuits and guard monitoring. Features:- Safe relay contacts:
- 3 safe, redundant relay contacts
- 1 auxiliary contact (status contact)
- Connection options:
- Emergency stop buttons
- Safety switches
- Non-contact safety switches
- Safety devices with OSSD outputs
- Operating modes:
- Single- or dual-channel operation available
- Monitoring functions:
- Feedback circuit for controlling downstream contactors or expansion modules
- Cyclical monitoring of output contacts
- Cross-fault and ground fault monitoring
- Start options:
- Monitored manual start
- Automatic start
- Safety standards:
- Stop function up to PL e / SIL 3 / Category 4 according to EN ISO 13849-1 and IEC 61508
- Status display:
- LED indicates the switching state
Functionality:- Normal operation:
- When the emergency stop circuit is closed (e.g., safety door is closed), the SR3C allows machine operation.
- Safety activation:
- When the safety function is triggered (e.g., safety door is opened), the device immediately interrupts the release current paths, safely shutting down the machine.
- Error detection:
- Force-guided relays and cyclical self-monitoring detect faults and ensure the reliability of the safety function.
Mounting and Installation:- Protection:
- Must be installed in control cabinets with at least IP54 protection according to EN 60204-1
- Mounting:
- Mounts on a 35 mm DIN rail according to EN 60715 TH35
- Spacing and cooling:
- Maintain at least 10 mm distance from adjacent devices for AC 115 V / 230 V variants
- Ensure adequate heat dissipation within the control cabinet
- Optional spacer (Part No. 472596 by ZANDER AACHEN) available
Certifications:- Germanischer Lloyd Certificate: TAE00003JF
Safety Instructions:- Installation and commissioning must only be performed by qualified personnel.
- Adherence to all relevant safety norms and regulations is required.
Included Items:Applications:- Emergency stop circuits for machinery and equipment
- Guard monitoring
- Control of safety-relevant components
- Applications requiring the highest safety standards (PL e / SIL 3 / Category 4)