Electronic built-in ballast for HI lamps (with cover) 70W Design: M3 Housing: aluminum Ignition voltage: max. 5kV Operating frequency: 173Hz Plug-in terminals with lever opener: 0.75-2.5qmm Temperature protection Constant power consumption Idle-proof For lamps of protection class I Protection type: IP20 Permissible load capacity: 20-120pF Radio interference suppressed Fastening tabs for M4 screws for mounting on the underside No flashing of defective lamps Housing: metal housing Type of dimming: without Protection class: I, MultiW version: No Version: electronic For lamp type HI: Yes Suitable for lamp power (1-lamp): 70W Nominal voltage from/to: 220-240V Length: 110mm Height: 23mm Width: 75mm
SM 231, ECO (231-1BD30)
Technical Data
Order no.: 231-1BD30
Type: SM 231, ECO
General Information:
- Note: -
- Features: 4x AI, 12 Bit, Voltage +/-10 V, Parameterizable
Current Consumption/Power Loss:
- Current consumption from backplane bus: 120 mA
- Power loss: 0.6 W
Technical Data Analog Inputs:
- Number of inputs: 4
- Cable length, shielded: 200 m
- Rated load voltage: -
- Current consumption from load voltage L+ (without load): -
- Voltage inputs: yes
- Min. input resistance (voltage range): 100 kOhm
- Input voltage ranges: -10 V ... +10 V
- Operational limit of voltage ranges: +/-0.2%
- Operational limit of voltage ranges with SFU: -
- Basic error limit voltage ranges: +/-0.1%
- Basic error limit voltage ranges with SFU: -
- Destruction limit voltage max.: 30 V
- Current inputs: -
- Max. input resistance (current range): -
- Input current ranges: -
- Operational limit of current ranges: -
- Operational limit of current ranges with SFU: -
- Basic error limit current ranges: -
- Radical error limit current ranges with SFU: -
- Destruction limit current inputs (electrical current): -
- Destruction limit current inputs (voltage): -
- Resistance inputs: -
- Resistance ranges: -
- Operational limit of resistor ranges: -
- Operational limit of resistor ranges with SFU: -
- Basic error limit: -
- Basic error limit with SFU: -
- Destruction limit resistance inputs: -
- Resistance thermometer inputs: -
- Resistance thermometer ranges: -
- Operational limit of resistance thermometer ranges: -
- Operational limit of resistance thermometer ranges with SFU: -
- Basic error limit thermoresistor ranges: -
- Basic error limit thermoresistor ranges with SFU: -
- Destruction limit resistance thermometer inputs: -
- Thermocouple inputs: -
- Thermocouple ranges: -
- Operational limit of thermocouple ranges: -
- Operational limit of thermocouple ranges with SFU: -
- Basic error limit thermocouple ranges: -
- Basic error limit thermocouple ranges with SFU: -
- Destruction limit thermocouple inputs: -
- Programmable temperature compensation: -
- External temperature compensation: -
- Internal temperature compensation: -
- Temperature error internal compensation: -
- Technical unit of temperature measurement: -
- Resolution in bit: 13
- Measurement principle: Successive approximation
- Basic conversion time: 2 ms / channel
- Noise suppression for frequency: f=50 Hz...400 Hz
- Input data size: 8 Byte
Status Information, Alarms, Diagnostics:
- Status display: none
- Interrupts: no
- Process alarm: no
- Diagnostic interrupt: no
- Diagnostic functions: no
- Diagnostics information read-out: none
- Supply voltage display: none
- Group error display: red SF LED
- Channel error display: none
Isolation:
- Between channels: -
- Between channels of groups: -
- Between channels and backplane bus: yes
- Between channels and power supply: -
- Max. potential difference between circuits: -
- Max. potential difference between inputs (Ucm): DC 2 V
- Max. potential difference between Mana and Mintern (Uiso): -
- Max. potential difference between inputs and Mana (Ucm): -
- Max. potential difference between inputs and Mintern (Uiso): DC 75 V/AC 50 V
- Max. potential difference between Mintern and outputs: -
-