| General |
| Conductor diameter | 0,6 mm |
| Wire insulation | PE |
| Nominal voltage | 225 V |
| Test voltage | 2000 V |
| Loop resistance | 130 Ohm/km |
| Current carrying capacity | 2,5 A |
| Operating capacity | 52 nF/km |
| Insulation resistance | 5 GOhm x km |
| Capacitive couplings K3 | 300 pF/400 pF |
| Line attenuation | 1,04 dB/km |
| Installation temperature range | -20 °C to +50 °C |
| Temperature range after installation | -30 °C to +70 °C |
| Bending radius | 7.5 x cable diameter |
| Sheath marking | Telephone handset, white marking |
| Stranding | Star quad, basic bundle, main bundle |
| Sheath | Aluminium tape shield with plastic coating and PE sheath |
| Conductor marking | black rings |
The VOKA telecommunication earth cable type A-2Y(L)2Y 4x2x0.6 is a specialised cable for underground installation in the field of telecommunication and telecommunications infrastructure. It is primarily used in low-frequency applications, particularly in trunk networks and in systems operating without spooling. The cable is designed for outdoor use and is suitable for example as a local access or local connection cable, as a railway station telecommunication cable, and in industrial plants. It is not approved for high-voltage installation purposes, but exclusively intended for telecommunication and signal transmission applications.
Applications
The cable is generally suitable for all operational sites, with special restrictions applying to mine operations according to DIN VDE 0118 Part 1 to Part 3. Cables with an outer PE sheath may only be used in fire- or explosion-hazardous areas if sufficient protective measures are in place. Installation is carried out by underground laying, with the cable structure designed for stable and long-lasting installation in the ground.
Functions and equipment in detail
The cable consists of single-strand, bare copper conductors with a diameter of 0.6 mm. The conductors are insulated with polyethylene (PE), ensuring high electrical insulation and mechanical stability. The conductor identification is achieved through black rings, enabling clear identification of individual conductors. The stranding is carried out in a star quad system, where 4 conductors form a star quad, 5 star quads form a basic bundle, and 5 or 10 basic bundles form a main bundle. These bundles are then stranded to form the cable core, with a core wrapping applied. The sheath consists of a layered sheath made of a 0.2 mm thick aluminium tape coated on both sides with plastic, and welded to a black PE sheath. The sheath marking is continuous, featuring the inscription “Fernsprech-Handapparat” and a white meter marking, enabling precise length determination.
Technology explained simply
The rated voltage is 225 V, with a test voltage of 2000 V, highlighting the cable’s electrical strength. The loop resistance is 130 Ohm/km, typical for a conductor size of 0.6 mm. The current-carrying capacity is 2.5 A, indicating the maximum current the cable can safely transmit. The operating capacitance is 52 nF/km, and the insulation resistance is 5 GOhm x km, indicating high insulation quality. The capacitive couplings (K3) are 300 pF/400 pF at 800 Hz and a length of 300 m, describing electromagnetic interference between conductors. The line attenuation is approximately 1.04 dB/km at 800 Hz, indicating signal losses over the cable length. The temperature ranges for installation are between -20 °C and +50 °C, and after installation between -30 °C and +70 °C, enabling broad usability under various climatic conditions. The bending radius is 7.5 times the cable diameter, ensuring safe bending without damaging the cable.
Compatibility and accessories
The cable is constructed according to DIN VDE 0816 Part 1 and designed for use in bundled stranding. It is optimised for low-frequency applications and is preferably used in systems operating without spooling. The use of PE-insulated cables allows for integration of conductors with periodically interrupted insulation for insulation monitoring, enabling continuous inspection of insulation integrity. The cable construction is designed for underground installation, with the layered sheath providing high mechanical stability and protection against external influences.
Installation and mounting
Installation is carried out by underground laying, with the specified temperature ranges and bending radius to be observed. The cables are designed for stable and durable installation, with core wrapping and layered sheath ensuring high mechanical strength. The meter marking on the sheath facilitates length measurement and positioning during installation.
Advantages in operation
The cable offers high electrical insulation, mechanical stability, and resistance to external influences. The PE insulation and layered sheath ensure long service life and reliable signal transmission. The continuous marking enables easy identification and maintenance. Use in low-frequency systems ensures stable and low-loss signal transmission, particularly in telecommunication and industrial applications.