| General |
| Category | Cat7A |
| Frequency | 1500 MHz |
| Shielding | S-STP (S/FTP) |
| Core construction | 4x2xAWG22/1 |
| Overall shield | Copper braid with twin wire |
| Core shielding | Foil shielded |
| Outer sheath material | halogen-free (LSZH) |
| Fire load class | Dca |
| Cable diameter | 8,4 mm |
| Colour | Yellow |
| Construction | Simplex |
The VOKA installation cable Cat7, type XLAN-1500S/FTP, is a high-quality data cable for use in structured cabling systems. It is supplied on a 500-meter reel and is specifically designed for indoor installation. The cable features a yellow outer jacket and is designed for use in networks with high requirements for bandwidth and signal integrity. It complies with Category Cat7A and supports frequencies up to 1500 MHz, making it suitable for future-oriented networks. The construction is based on an S-STP (S/FTP) shielding principle, where each pair of conductors is individually shielded with foil and additionally protected by an overall shield made of copper braid with twin wire, which surrounds the entire cable. This ensures high shielding effectiveness against electromagnetic interference and minimizes crosstalk. The outer jacket is made of halogen-free material (LSZH), which reduces the formation of toxic smoke gases in case of fire and meets fire load class Dca. The cable diameter is 8.4 mm, which provides good installation properties and flexibility during installation.
Applications
The cable is suitable for use in office buildings, industrial facilities, server rooms, and other environments where stable and high-performance data transmission is required. It is particularly suitable for applications requiring high data rates, such as Gigabit and 10-Gigabit Ethernet, as well as for future requirements that exceed current standards. Use in structured cabling systems enables centralized management and maintenance of the network infrastructure.
Functions and Equipment in Detail
The cable is designed as a simplex cable, meaning it is intended for connecting end devices with network interfaces (e.g., switches, routers, PCs). Each pair of conductors is shielded with foil, ensuring effective protection against electromagnetic interference (EMI) and crosstalk. The overall shield made of copper braid with twin wire provides additional protection and ensures high signal quality. The use of AWG22 (approximately 0.5 mm²) for individual conductors ensures sufficient conductivity and low signal loss. The yellow color of the outer jacket facilitates identification and categorization within the cabling system.
Technology Explained Simply
The designation S-STP (S/FTP) describes the shielding construction: “S” stands for “Screened” (shielded), “FTP” for “Foil Twisted Pair” (foil-shielded twisted pairs). The additional overall shield made of copper braid protects the entire cable from external electromagnetic interference. The designation Cat7A refers to the cable category, which supports a maximum frequency of 1500 MHz. This enables data transmission rates up to 10 Gbit/s over long distances. The materials are halogen-free (LSZH), which reduces the formation of toxic smoke gases in case of fire and increases safety. Fire load class Dca is a measure of the cable’s fire behavior and complies with the requirements of EN 50575.
Compatibility and Accessories
The cable is compatible with a wide range of network accessories, particularly with CAT6A- and CAT7A-compatible components. Compatible products include, for example, patch panels with 8 or 24 ports, Keystone modules in various designs (e.g., slim-line, with dust cover, with cable clamp), tool-free TP connectors, and wire stripping tools. The use of cable ties, Velcro tape, and cable organizers supports orderly and structured installation. Combining the cable with CAT6A- and CAT7A-compatible connectors and sockets ensures a stable and reliable connection.
Installation and Mounting
Installation is carried out in the usual manner for installation cables: the cable is routed along predefined paths (e.g., in cable ducts, on trays, or in wall conduits). The 500 m reel enables efficient installation over long distances. During installation, care must be taken to ensure clean stripping and correct connection of the conductors to the connectors. Tool-free TP connectors simplify installation, as they can be terminated without special tools. The use of wire stripping tools ensures precise and clean processing of the conductors. The cable diameter of 8.4 mm requires sufficient space in the cable ducts to avoid mechanical damage.
Operational Advantages
The cable offers high signal quality and low error susceptibility, resulting in a stable network connection. The high shielding minimizes interference and ensures reliable data transmission, even in environments with high electromagnetic interference levels. The halogen-free design increases safety in case of fire. Use in structured cabling systems enables easy maintenance and expansion of the infrastructure. The 500 m reel allows for economical and efficient installation over long distances.