| General |
| Cable type | Cat7 - |
| Shielding | S-STP (S/FTP) - |
| Pair shielding | Foil shielded - |
| Overall shield | Copper braid with twin wire - |
| Braided density | 40% - |
| Insulation | halogen-free (LSZH) - |
| Colour | Orange - |
| Fire load class | Dca - |
| Bandwidth | 1000 MHz |
The VOKA brand installation cable, type SLAN1000FRNCSTP-C4PRAWG23, is a
Cat7 data cable with a length of 100 meters, designed for use in structured cabling systems. It is intended for data transmission in networks with high speeds and is suitable for use in offices, server rooms, or industrial environments. The cable is configured as
S-STP (S/FTP), meaning each pair of conductors is individually shielded with foil, and additionally features an overall shield made of copper braid with twin wire. This shielding ensures high immunity against electromagnetic interference and prevents signal radiation, which is particularly important in environments with high electromagnetic influence.
Applications
This cable is designed for use in modern network infrastructures supporting bandwidths up to 1000 MHz. It is suitable for connecting network devices such as switches, routers, workstations, and servers. Due to its high shielding and installation properties, it is also suitable for use in environments with increased requirements for signal integrity, such as data centers or industrial facilities. The installation method allows for easy deployment in cable ducts, raceways, or under plaster.
Functions and Features in Detail
The cable features
halogen-free insulation (LSZH), which produces minimal smoke and does not release toxic halogens in case of fire. This increases safety in the application environment, especially in enclosed spaces. The cable color is
orange, which visually distinguishes it from other cable types and enables easy identification in cable management. The designation “light variant” indicates a reduced braid density of 40%, which reduces weight and improves installation properties without significantly impairing shielding effectiveness. The fire load class
Dca meets the requirements for fire resistance according to EN 50575 and is suitable for use in buildings with enhanced fire protection requirements.
Technology Explained Simply
The designation
Cat7 refers to a cable category designed for data transmission rates up to 10 Gbit/s over distances of up to 100 meters. The shielding technology S-STP (S/FTP) provides a double layer of protection: each of the four conductor pairs is wrapped in a metallic foil, and the entire cable is surrounded by a copper braid. This construction minimizes interference from external electromagnetic fields and simultaneously prevents signal radiation from the cable. The copper braid with twin wire ensures particularly effective shielding, especially at high frequencies. The use of copper conductors guarantees high conductivity and signal stability.
Compatibility and Accessories
The cable is compatible with a wide range of network accessories, particularly with
Keystone modules and
patch panels of category
CAT6A and higher. It can be connected with
TP connectors that are tool-free to terminate, which speeds up installation. Suitable accessories include, for example, Keystone modules with RJ45 sockets, patch panels in 8- or 24-port configurations, as well as cable ties and Velcro straps for proper securing and routing of the cables. The use of tools such as a
TP stripping tool facilitates precise preparation of cable ends.
Installation and Mounting
Installation is typically carried out by professionals in the field of electrical or IT cabling. The cable can be installed in cable ducts, raceways, or under plaster. Due to its installation properties and reduced braid density, it is flexible and can be bent and routed without requiring significant force. The ends are terminated with appropriate connectors, such as tool-free TP connectors. Connections are made to patch panels or directly to network devices via RJ45 sockets. The use of cable ties or Velcro straps ensures proper routing and prevents tangling.
Operational Advantages
The cable offers high signal quality and reliability at high data rates. The double shielding ensures minimal interference, which is particularly beneficial in environments with many electrical devices. The halogen-free insulation increases safety in case of fire. The orange color facilitates identification in cable management. The installation properties and reduced braid density (light variant) simplify installation and reduce space requirements in cable ducts. Compatibility with CAT6A and higher components enables future-proof network equipment.
Note: Batteries or other accessories not mentioned are not included in the delivery scope.